11 41555-01
Air Purier Maintenance
PREFILTER
HOOK
TAPE
HOOK
TAPE
6. Place the front grill back onto the unit. First, line up the tab on the bottom
of the grill with the recess on the purier base and then push the top of the
grill forward until it is closed. Refer to Figs. 6 and 7 (pg. 7). NOTE: This unit
will not operate unless the grill is in the correct position.
7. Plug in the air purier.
8. To reset the counter to zero hours and turn o the indicator, simply press and
hold the PREFILTER RESET key for three seconds. Then, you must release
the reset key and then press and hold the pre-lter reset key again for three
seconds to turn o the lter indicator.
Cleaning the Cleanable Filter
The PermaLife™ Filtration System uses a cleanable lter that never has to be changed,
only cleaned. When the cleanable lter run time exceeds 2800 hours (approximately 4 to
6 months of use), the Cleanable Filter Life Counter will display 0% life remaining and the
Cleanable Filter indicator will ash (refer to Filter Life Counters for additional information,
pg. 8). This is a reminder that you should check the lter and clean if necessary. The proper
time to clean the cleanable lter depends on usage and the environment. Use the following
list to help determine if the lter should be cleaned:
• Compare the color of the cleanable lter to the color coded chart on the inside of the
housing. If the cleanable lter color matches the darkest color on the chart, you should
clean the cleanable lter.
• If you notice a decrease in air output or an increase in noise at any time during normal
operation, the cleanable lter may be clogged and need cleaning.
To clean the cleanable lter and reset the Cleanable Filter Life Counter:
1. First, turn o and unplug the air purier.