Getting Started 7
A manufacturer’s identification label is on the rear of the 
balancer.
Figure 7: Manufacturer ID label
Specific Precautions/Power Source
The Road Force
®
 Elite GSP9700 Balancer is intended to 
operate from a power source that will apply 230VAC 
+10% / -15%, 1 phase, 10 amp 50/60 Hz, power.
The power cable includes a NEMA 20 amp plug, L6-20P, 
between the supply conductors of the power cord and uti-
lizes a twist lock connector.
Figure 8: : NEMA L6-20P Plug
Optical Scan Laser Precaution 
The Optical Scan Laser is a class 1 laser designed to 
measure the profile of wheel assemblies. The laser is not 
a field serviceable part. No maintenance is to be per-
formed on the laser.)
Figure 9: Class 1 Laser Warning
Wavelength: 650nm.
HammerHead
®
 TDC Laser Precaution
The TDC (Top Dead Center) Laser Indicator is a class 
2M laser designed to aid in applying clip-on weights. This 
is an option feature that is not a field serviceable. Laser 
Radiation - Do not stare into the beam or view directly 
with optical instruments.
Figure 10: Class 2m Laser warning
Turning Power ON/OFF
Push Button Switch. 
Balance is equipped with a push button power switch 
located on the left side of the LCD support. Use this 
switch for normal shut down and restarting procedures.
Figure 11: push button power
A protective ground connection is essential for 
safe operation.
Always use the push button switch on the LCD 
support to power the balancer on/off to prevent 
data loss