Getting Started 8
Main Power Switch
The main power ON/OFF switch is located on the back of 
the balancer cabinet. 
To power the balancer “ON,” press the “I” side of the ON/
OFF switch. To turn all power the balancer “OFF,” press 
the “O” side of the ON/OFF switch.
Figure 12: Main Power Switch
Equipment Specifications
Certain Features:
Balancer may include certain features equipment: 
• Road Force® uses a roller that applies a load to the 
tire in order to take road force measurements
Figure 13: Road Force
• SpeedClamp® pneumatically clamps the wheel onto 
the shaft for balancing.
Figure 14: SpeedClamp®
• HammerHead® top-dead-center laser automatically 
displays a vivid line at top dead center after a wheel 
has been spun.
Figure 15: HammerHead®
Electrical
Voltage:  230VAC +10% / -15%, 1 
phase, 50/60 Hz, power cable 
includes NEMA 20 amp plug, 
L6-20P
Amperage:  10 amperes
Wattage: 3450 watts (peak)
Air
Air Pressure Requirements: 100-175 PSI (6.9-12.0 bar)
Approximate Air Consumption: 4 CFM (113 Liters/Minute)
Atmospherics
Temperature: +32°F to +122°F (0°C to 
+50°C)
Relative Humidity: Up to 95% Non-condensing
Altitude: Up to 10000 ft. (3048 m)
Sound Pressure Level
Equivalent continuous A-weighted sound pressure at operator’s 
position does not exceed 70 dB (A).