1. Turn the adjustment screw for the oil pump. Use a
screwdriver or combination wrench.
a) Turn the adjustment screw clockwise to decrease
the chain oil flow.
b) Turn the adjustment screw counterclockwise to
increase the chain oil flow.
+
Recommended settings for the oil pump
Guide bar length 38-46 cm/15-18 in: Medium flow
Guide bar length 50-71 cm/20-28 in: Maximum flow
Air cleaning system
AirInjection
is a centrifugal air cleaning system that
removes dust and dirt before the particles are caught by
the air filter. AirInjection
extends the life of the air filter
and the engine.
To clean the cooling system
The cooling system keeps the engine temperature
down. The cooling system includes the air intake on the
starter (A), the pawls on the flywheel (B), the cooling
fins on the cylinder (C), the cooling channel (D) and the
cylinder cover (E).
B
A
C
D
E
1. Clean the cooling system with a brush weekly or
more frequently if it is necessary.
2. Make sure that the cooling system is not dirty or
blocked.
CAUTION: A dirty or blocked
cooling system can make the product
too hot, which can cause damage to the
product.