REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Discharge Air (F) 35
Evaporator (F) 25
ote: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
½ Case
tu/hr/tota
*
Parallel 10,500
Conventional 12,075
Full Case
tu/hr
total*
Parallel 21,000
Conventional 24,150
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
DEFROST DATA
Frequency Hrs 4
OFFTIME
Temp Term °F 54
Failsafe Minutes 24
ELECTRIC or GAS Not Recommended
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 ½*
Merchandiser Liquid Line (in.) 3/8*
Merchandiser Suction Line (in.) 5/8*
Estimated Charge (lb)***
4ft 1.2
5ft 1.5
6ft 1.8
*Dependent on case length and refrigerant type.
*** This is an average for all refrigerants types. Actual
refrigerant charge may vary by approximately half a
ound.
GLYCOL REQUIREMENTS
GPM PSI
NA NA
NA NA
NA NA