HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
LWU Technical Data Sheet4 of 6
Impact LWU
Frozen Food & Ice Cream
Electrical Data
90 in. 138 in.
Number of Fans – 4W 3 5
(Energy Efficient fan motors are not available for End or End-compartment models)
Amperes Watts
90 in. 138 in. 90 in. 138 in.
Evaporator Fans
120V 60Hz Standard 0.93 1.55 72 120
120V 50Hz Standard NA
230V 60Hz Export 0.45 0.75 72 120
230V 50Hz Export 0.74 1.10 111 165
120V 60Hz Energy Efficient 0.42 0.70 30 50
230V 60Hz Energy Efficient NA
Nosing Anti-sweat Heaters (on fan circuit)
120V 50Hz / 60Hz 1.87 2.83 226 338
230V 50Hz / 60Hz 0.98 1.47 226 338
Cycling Anti-sweat Heaters
120V 50Hz / 60Hz NA
230V 50Hz / 60Hz NA
Minimum Circuit Ampacity
120V 60Hz Standard 3.0 4.58
120V 50Hz Standard NA
230V 60Hz Export 2.63 2.42
230V 50Hz Export 1.92 2.77
120V 60Hz Energy Efficient 2.49 3.73
230V 60Hz Energy Efficient NA
Maximum Over Current Protection 120V 20 20
Maximum Over Current Protection 230V 15 15
Electric Defrost Heaters
208V 60Hz Standard Front Compartment 4.00 8.00 835 1670
208V 60Hz Standard Rear Compartment 4.00 8.00 835 1670
208V 60Hz Standard End Compartment 5.50 5.50 1150 1150
230V 50Hz Export Front Compartment 4.40 8.90 1012 2047
230V 50Hz Export Rear Compartment 4.40 8.90 1012 2047
230V 50Hz Export End Compartment 6.10 6.10 1403 1403
Koolgas Drip Pan Heaters
120V 60Hz Standard 3.75 6.25 450 750
230V 50Hz Export NA
Standard Lighting: None