PN_3155541_C U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
44 sErvIcE
REPLACING INVERTER
(Applies only for VRL2 and VRL3)
Unplug the power cord before servicing.
1. Remove product and place in a refrigerated area.
Make sure the power is off to the case.
2. Make sure there is no voltage in the refrigerator. Remove rear lower panel as shown below.
Product will be degraded and may spoil if
allowed to sit in a non-refrigerated area.
VRL3B1A Shown
Parts may be ordered at Hussmann’s Performance
Parts e-store:
https://parts.hussmann.com/
or
Call toll free: 855-487-7778
Required Tools:
• Screwdriver / Philips Tip
• 1/4" Allen Wrench
REMOVE CONDENSING UNIT
STOPPER
A