HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
VRL Merchandisers
P/N 3034040_H 43
DEFROST DATA
Frequency (hr) 12
ELECTRIC DEFROST
Failsafe (minutes)
All models 35
Defrost Termination
Temperature (°F) 48
PHYSICAL DATA
Refrigerant Charge (R290)
(0.150 kg each system)
VRL3B 10.6 oz 0.300 kg (2 systems)
VRL2B 5.3 oz 0.150 kg (1 system)
VRL1B 4.58 oz 0.130 kg (1 system)
Note:
This data is based on store temperature and humidity that does not exceed 80°F and 55% R.H. unless otherwise stated.
Schedule defrost at night while lights are off.
Electrical Data
(2 Condensing Units for VRL3)
1
0.3
Compressor RLA 4.8 4.8 4.45
Note: Run Amps values obtained under ambient condions of 75°F and 55 % RH having IAT of Frozen Food category 0°F
following ASHRAE 72 method. Serial plate Total Amps obtained under UL471 tesng condions.