18 ElEctrIcal / rEfrIgEratIon / controllEr
REFRIGERATION SYSTEM
FUNCTIONALITY
These cases can be used for frozen food. These
merchandiser model is self-contained and has
a controller that automates the refrigeration
cycle and the defrost cycle.
During refrigeration mode, the discharge line
solenoid valve (RSV) is energized and held
open, allowing the gas to flow through the
condenser.
Once the refrigerant is in a liquid state, a
capillary tube is used as an expansion device
that feeds the evaporator.
During refrigeration mode, hot gas solenoid
valve (HGSV) is deenergized and closed.
Figure A. System Diagram- Refrigeration Mode
(This diagram is applicable for both 1 and 2-door models)
GDF 3.0 SHEET SIZE D
NOTES:
1. APPLICABLE STANDARDS / SPECIFICATIONS
ASME Y14.5M-1994, DIMENSIONS AND TOLERANCES
2. KEY PRODUCT CHARACTERISTICS PER EPR-0006 & IDENTIFIED WITH SYMBOL
3. MATERIAL- Error: No reference
4. REF -
K
SHEET 1 OF 2
P/N
REV
THIRD
ANGLE
PROJECTION
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES.
R
REVISION HISTORY
REV ECN DATE REVISION DESCRIPTION REV BY CHKD BY APPR BY
FILTER
DRIER
CAP TUBE
CHECK
VALVE
EVAPORATOR
CONDENSER
CONDENSATE PAN
HGSV
RSV
COMPRESSOR
REFRIGERATION
PRESSURE
SWITCH