4
5. OPERATION

is heating.
USE THE LOWEST ACCEPTABLE TEMPERATURE SETTING TO
SAVE ENERGY.

TO CHILDREN OR THE INFIRM. A THERMOSTATIC BLENDING
VALVE IS RECOMMENDED IN HIGH RISK SITUATIONS.
6. 
AND ANODE REPLACEMENT
DISCONNECT ELECTRICITY SUPPLY BEFORE MAINTENANCE.
A re-settable safety thermal cut-out switches off the element in the event of the
unit over-heating.
The thermal cut-out may trip occasionally in normal use. If this happens the heater
will not heat water and the element light will not come on.
The thermal cut-out is located underneath the unit behind the grey access plate.

unit for ease of access to the cutout.

Drain water from heater and locate grey access plate.
Remove the cover retaining screws and gently prise cover off.

Element ange - remove to access anode.
Thermal cutout -
Press to reset.
Element securing bolt (x4)
Allen key required to remove.