SPECIFICATIONS
Typical test condions, unless otherwise specied: Ambient Temp =73+/-3°F, RH=50%-70%,
Altude=0~100 meter
DISCLAIMERS
This device is not intended for workplace hazard CO
2
monitoring, nor intended as a denive monitor
for human or animal health instuons, life sustenance, or any medical-related situaon.
Hydrofarm and the manufacturer assume no responsibility for any damage or loss suered by the user
or any third party arising through the use of this product or its malfuncon.
Hydrofarm reserves the right to change the specicaons without noce.
MEASUREMENT SPECIFICATION
Operang Temperature 32°F to 122°F (0°C to 50°C)
Storage Temperature -4°F to 140°F (-20°C to 60°C)
Operang & Storage RH 0-95%, non-condensing
CO
2
Measurement
Accuracy at 0~3000 ppm ±50 ppm or ±5% of reading, whichever is greater
Accuracy over 3000 ppm ±7%
Repeatability 20 ppm at 400 ppm (standard dev. of 10 readings in 1 minute)
Measurement Range 0-5000 ppm
Display Resoluon 1 ppm (0-1000); 5 ppm (1000-2000); 10 ppm (>2000)
Temp Dependence
±0.2% of reading per °C or ±2ppm per °C, whichever is greater,
referenced to 25°C
Pressure Dependence 0.13% of reading per mmHg (corrected by user’s altude input)
Response Time <2 min for 63% of step change or <4.6 min for 90% step change
Warm-up Time <30 sec
Power input AC 100 ~ 240 VAC
Dimension
Sensor Unit: 153x33x27mm (6.0"x1.3"x1.1")
Control Unit: 195x145x44mm (7.7"x5.7"x1.7")
Weight 700 g (24.7 oz)
6