INSTRUCTIONS
APDPX2
PX2 ADVANCED LIGHTING CONTROLLER
INSTRUCTIONS EN FRANÇAIS ..... 24
PX2 CONTRÔLEUR AVANCÉ D’ÉCLAIRAGE
INSTRUCCIONES EN ESPAÑOL .... 46
CONTROLADOR DE ILUMINACIÓN AVANZADA PX2

Questions and Answers

  • D
    David LawsonAug 17, 2025
    Why do my Hydrofarm Controller fixtures fail to turn off?
    • R
      Roger SmithAug 17, 2025
      If Hydrofarm Controller fixtures fail to turn off, it might be due to having too many fixtures, which can cause residual voltage in the cable system. Try reducing the number of fixtures per zone to resolve this issue.
  • D
    dbaldwinAug 19, 2025
    How to fix Hydrofarm Autopilot PX2 screen when it does not work after connecting power supply?
    • L
      Laura MillsAug 19, 2025
      If the Hydrofarm Controller screen isn't working after you've connected the power supply, unplug the DC connector from the controller momentarily. Then, reconnect it, making sure the connector is fully inserted and tightened.
  • L
    lprattAug 22, 2025
    What to do if Hydrofarm Autopilot PX2 Controller does not control fixtures?
    • J
      James GarciaAug 22, 2025
      If the Hydrofarm Controller isn't controlling the fixtures, try reconnecting the signal cable. Then, check each fixture individually to find where the communication is being lost.
  • W
    williammullinsAug 26, 2025
    What to do if Hydrofarm Autopilot PX2 Controller does not show temperature after connecting with temperature probe?
    • B
      brad59Aug 26, 2025
      If the Hydrofarm Controller isn't showing the temperature after you connect the temperature probe, try disconnecting and then reconnecting the temperature probe.
  • K
    Katherine BenderAug 27, 2025
    What to do if fixture status is different from the power set by Hydrofarm Autopilot PX2 Controller?
    • M
      Mr. Gordon Porter IVAug 28, 2025
      If the fixture status is different from the power set by the Hydrofarm Controller, adjust the time of sunrise and sunset or reset the temperature limits.
  • J
    Jonathan SmithAug 31, 2025
    What to do if some Hydrofarm Autopilot PX2 fixtures work normally, while others function abnormally?
    • L
      lrayAug 31, 2025
      If, when connecting several fixtures, the first few work fine but the rest don't function properly with your Hydrofarm Controller, try reconnecting the signal cable. Also, check for and replace any damaged fixtures.
  • J
    Joshua WardSep 2, 2025
    Why won't my Hydrofarm Controller fixtures turn off?
    • R
      Raymond MartinSep 2, 2025
      If your Hydrofarm Controller fixtures are not turning off, it may be due to having too many fixtures connected, which can cause residual voltage in the cable system. Try reducing the number of fixtures per zone.
  • K
    Kimberly RhodesSep 5, 2025
    How to fix Hydrofarm Controller screen that does not work after connecting power supply?
    • R
      Richard ButlerSep 5, 2025
      If the screen on your Hydrofarm Controller isn't working after connecting the power supply, unplug the DC connector from the controller momentarily, then reconnect it. Make sure the connector is fully inserted and tightened.
  • E
    Eric WilliamsSep 8, 2025
    What to do if some fixtures work abnormally when connecting several fixtures to the Hydrofarm Autopilot PX2?
    • G
      gcookeSep 8, 2025
      If some fixtures function abnormally when connecting several fixtures to the Hydrofarm Controller, try reconnecting the signal cable. If the problem persists, replace any damaged fixture.
  • S
    Steven SullivanSep 12, 2025
    How to fix a Hydrofarm Autopilot PX2 screen that doesn't work after connecting the power supply?
    • K
      kevin76Sep 12, 2025
      If the screen of your Hydrofarm Controller doesn't work after connecting the power supply, unplug the DC connector from the controller momentarily, then reconnect it. Ensure the connector is fully inserted.

Summary

Product Overview

Key Features and Benefits

Independent zone control, spectral optimization, power saving, and advanced features like dimming.

Temperature Sensing and Protection

Two sensors provide data for auto-dimming and high-temperature shutdown.

Cabling and Infrastructure Benefits

Shielded cables for reliability, eliminates traditional contactors, reduces infrastructure cost.

Package Contents

Lists all items included in the Autopilot PX2 controller package.

Technical Specifications

Details voltage, frequency, and control capacity for HID and LED fixtures.

Installing the PX2

Controller Mounting

Securely mount the PX2 controller to a wall using provided screws and holes.

Power and Probe Connections

Connect the power adapter and attach temperature/signal probes to the bottom panel.

Cable Management and Placement

Route probe cables neatly to the ceiling, ideally suspending them.

Temperature Probe Placement

Shield probes from direct light to prevent inaccurate readings and premature dimming.

Analog;Digital Configuration

Analog Setup Mode

Configure zones for controlling up to 50 LED fixtures each.

Digital Setup Mode

Configure zones for controlling up to 256 HID fixtures each.

Mixed Analog;Digital Mode

Set Zone A for LEDs and Zone B for HIDs.

System Settings Menu

Configure units (temp, power), time format, time, and date for the controller.

Zone A Setup

Navigating Setup Options

Cycle through Zone A/B Setup and Output Schedule, and System Setting.

Zone A Parameter Configuration

Set Type, Power, R/S, Dim, Stop, and Delay for Zone A.

Saving Zone Configuration

All settings must be saved for the controller to function properly.

Zone B Configuration

Repeat the setup process for Zone B.

Zone A Output Schedule

Programming Light Output

Schedule up to six output levels (wattage/percentage) for the light cycle.

Saving Output Schedules

Save the programmed schedule for Zone A and repeat for Zone B.

Lighting Layout Guides

Refer to pages 8-23 for detailed cable guides on various lighting configurations.

LED Indicators and Troubleshooting

Understanding LED Indicators

Meaning of controller LEDs (A-G) for status, protection, and signal output.

Resolving Common Issues

Solutions for problems like screen errors, fixture control issues, and temperature probe detection.

Cable Guide: PHOTOBIO LED Fixtures

PHOTO-LOC Cable Kit Instructions

Connect PHOTOBIO fixtures using the PHOTO-LOC 0-10V cable kit.

LED Fixture Connection Legend

Identifies cable ends (Female, Male) and T Connector for LED fixtures.

Cable Guide: PHANTOM HID Fixtures

RJ Data Link Cable Setup

Connects Phantom HID fixtures using RJ data link and RJ12 T-connectors.

HID Fixture Connection Legend

Legend for HID connections: RJ Data Link, RJ12 T-Connector, RJ12 to USB.

Cable Guide: CORE 2.0 HID Fixtures

IP Rated Data Link Cable

Connects Core 2.0 fixtures using IP rated data link and Wieland harness.

Core 2.0 Dimmable Legend

Legend for Core 2.0 connections: Data Link, Wieland Harness, Junction Box, Input/Output.

Cable Guide: LED + DUAL CMH Checkerboard

PHOTO-LOC Cable Kit for Mixed Tech

Connects LED and CMH fixtures using the PHOTO-LOC 0-10V cable kit.

LED & HID Connection Legends

Legends for LED (PHOTO-LOC) and HID (RJ12) connections in mixed setups.

Cable Guide: LED + DE HPS Checkerboard

PHOTO-LOC Cable Kit for Mixed Tech

Connects LED and HPS fixtures using the PHOTO-LOC 0-10V cable kit.

LED & HID Connection Legends

Legends for LED (PHOTO-LOC) and HID (RJ12) connections in mixed setups.

Cable Guide: DUAL ZONE DE HPS Checkerboard

RJ Data Link Cable for HPS

Connects dual zone HPS fixtures using RJ data link and RJ12 T-connectors.

HID Fixture Connection Legend

Legend for HID connections: Data Link, RJ12 T-Conn, RJ12 to USB.

Cable Guide: DE HPS + DUAL CMH Checkerboard

RJ Data Link Cable for HPS;CMH

Connects HPS and CMH fixtures using RJ data link and RJ12 T-connectors.

HID Fixture Connection Legend

Legend for HID connections: Data Link, RJ12 T-Conn, RJ12 to USB.

Cable Guide: DE HPS + DE MH Checkerboard

RJ Data Link Cable for HPS;MH

Connects HPS and MH fixtures using RJ data link and RJ12 T-connectors.

HID Fixture Connection Legend

Legend for HID connections: Data Link, RJ12 T-Conn, RJ12 to USB.

Product Warranty Information

Limited Warranty Terms

Covers defects for 3 years; excludes misuse, abuse, or failure to follow instructions.

Liability and Damage Exclusions

Liability limited to replacement cost; excludes consequential or incidental damages.

Warranty Service Process

Return product to place of purchase with receipt for repair or replacement.

Hydrofarm Autopilot PX2 Specifications

General IconGeneral
TypeEnvironmental Controller
Amperage15A
Power Consumption1800W
Number of Outlets2
Control Outputs2
DisplayLCD
Timer FunctionYes
Temperature Range32°F to 122°F (0°C to 50°C)
Voltage120V

Related product manuals