ZONE A SETUP
Press
to cycle through the following
opons: Zone A Setup; Zone A Output
Schedule; Zone B Setup; Zone B Output
Schedule; and System Seng.
NOTE: If there is no acvity for 15
seconds while seng up, the controller
will automacally go back to the HOME
page.
All sengs must be saved by pressing
for the controller to operate.
1. Press
and enter the ZONE A menu.
2. Press
to cursor through the values and highlight the value you want to change.
Value Descripon
Type Type of lights installed in ZONE A (or B): 250W, 315W, 400W, 600W, 630W,
750W, 945W, 1000W HPS/CMH, 320W LED, 480W LED, 600W LED, 640W LED,
680W LED, 2x315W, 2x600W.
Power Select percentage or waage for the xtures.
R/S (0–30 min) The me lights will take to gradually reach full power (R=sunrise) or
turn o (S=sunset).
Dim The temperature limit at which the lights will auto-dim.
Stop The temperature limit at which the lights will auto-shutdown.
Delay (0–30 min) Hot start prevenon to allow HID lamps adequate me to cool to
prevent lamp damage. For HID, minimum seng should be 15 min. For LED,
seng can be 0 min.
3. Press or to select the correct seng, then press to conrm.
4. Repeat steps 2–3 to set all values.
5. Press
to save the sengs.
6. Repeat steps for ZONE B.