EasyManua.ls Logo

Hydrofarm Autopilot PX2 - LED Indicators and Troubleshooting; Understanding LED Indicators; Resolving Common Issues

Default Icon
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
A
C EDB F G
Indicator Meaning
A, C
LED on green: Normal status. Screen display: NML
LED on yellow: Over-temperature dimming protecon. Screen display: DIM
LED ashes red: Over-temperature lamp-o protecon or temperature exceeds 80°C.
Screen display: SOS
LED ashes yellow: Temperature control line is not inserted. Screen display: NO PROBE
B, D
LED LIGHT ON: Lamp on. LED LIGHT OFF: Lamp o.
E
If the ANALOG indicator is on, the controller outputs 0–11.5V signals.
F
If the DIGITAL indicator is on, the controller outputs RS485 signals.
E, F
The ANALOG and DIGITAL indicators are both on.
ZONE A is the analog signal output, and ZONE B is the digital signal output.
G
The output signal mode can be switched by clicking the SET buon with a pen.
TROUBLESHOOTING
PROBLEM CHECK SOLUTIONS
Screen does not work aer
connecng power supply
Check if the power supply/
adapter/controller works
normally
Unplug DC connector from the
controller momentarily then
reconnect taking care to ensure
the connector is fully inserted
Controller does not control
xtures
Check if the signal cable is
connected well
Reconnect the signal cable
Controller does not show
temperature aer connecng
with temperature probe
Check if the temperature
probe is not connected
correctly
Reconnect the temperature
probe
Fixture power is dierent from
the power set by controller
Check if the ballast is under
sunrise and sunset mode or
if the temperature is under
temperature protecon mode
Reset the me of sunrise and
sunset or reset the temperature
limits
When connecng several xtures,
the rst several xtures work
normally, while the following
xtures funcon abnormally
Check if the signal cable is
connected well, or if the
xture is damaged, or the LED
status on xtures
Reconnect the signal cable, or
replace any damaged xture
LED INDICATORS

Related product manuals