7
A
C EDB F G
Indicator Meaning
A, C
LED on green: Normal status. Screen display: NML
LED on yellow: Over-temperature dimming protecon. Screen display: DIM
LED ashes red: Over-temperature lamp-o protecon or temperature exceeds 80°C.
Screen display: SOS
LED ashes yellow: Temperature control line is not inserted. Screen display: NO PROBE
B, D
LED LIGHT ON: Lamp on. LED LIGHT OFF: Lamp o.
E
If the ANALOG indicator is on, the controller outputs 0–11.5V signals.
F
If the DIGITAL indicator is on, the controller outputs RS485 signals.
E, F
The ANALOG and DIGITAL indicators are both on.
ZONE A is the analog signal output, and ZONE B is the digital signal output.
G
The output signal mode can be switched by clicking the SET buon with a pen.
TROUBLESHOOTING
PROBLEM CHECK SOLUTIONS
Screen does not work aer
connecng power supply
Check if the power supply/
adapter/controller works
normally
Unplug DC connector from the
controller momentarily then
reconnect taking care to ensure
the connector is fully inserted
Controller does not control
xtures
Check if the signal cable is
connected well
Reconnect the signal cable
Controller does not show
temperature aer connecng
with temperature probe
Check if the temperature
probe is not connected
correctly
Reconnect the temperature
probe
Fixture power is dierent from
the power set by controller
Check if the ballast is under
sunrise and sunset mode or
if the temperature is under
temperature protecon mode
Reset the me of sunrise and
sunset or reset the temperature
limits
When connecng several xtures,
the rst several xtures work
normally, while the following
xtures funcon abnormally
Check if the signal cable is
connected well, or if the
xture is damaged, or the LED
status on xtures
Reconnect the signal cable, or
replace any damaged xture
LED INDICATORS