FILL THE TUB SLOWLY SO FILLING CAN BE STOPPED IF A LEAK IS DETECTED. DRAIN
THE TUB IMMEDIATELY IF A LEAK IS DETECTED AND CORRECT THE PROBLEM
BEFORE RETESTING.
IMPROPER INSTALLATION OF THE TRANQUILITY HEATER CAN RESULT IN WATER
LEAKING FROM THE PLUMBING SYSTEM! WATER DAMAGE CAN OCCUR TO SPACES
BELOW OR ADJACENT TO THE BATHTUB.
Do not leave the tub unattended during the testing process and only fill the tub with enough
water to exceed the level of the return fitting.
After allowing the glue joints to dry for 24-hours, a STATIC leak test must be performed. You
can accomplish this by SLOWLY filling the tub with COLD WATER until the water level at least
2” above the highest jet.
If no leaks were detected, a PRESSURE leak test must be performed. Perform this final
REQUIRED leak test by activating the Tranquility System. Allow the system to run for 15-20
minutes minimum. The cold water will allow you to verify that the “Heater On” indicator is
illuminated on your Tranquility heater. If the light does not illuminate or if you encounter any
other problems, refer to the Troubleshooting section of these instructions.
IF NO LEAKS WERE DETECTED AND YOU HAVE VERIFIED THAT
YOUR TRANQUILITY HEATER IS FUNCTIONING PROPERLY,
CONGRATULATIONS, THE INSTALLATION OF YOUR TRANQUILITY
HEATER IS COMPLETE. YOU CAN NOW RELAX AND ENJOY THE
COMFORT YOU WILL EXPERIENCE IN YOUR HEATED BATHTUB.
TEST YOUR INSTALLATION
7