HYQUEST SOLUTIONS PTY LTD
Tipping Bucket Raingauge TB3 100-06 Issue 12: 29/7/2014
i. Site Selection
Rainfall measurements are intended to be representative of the actual rain falling on a given
area. Some of the more important factors which influence the representativeness of a gauge
are as follows:
Site the gauge on level ground where possible. Avoid sloping sites.
Site should have adequate protection from strong winds.
Site should be free of large obstructions such as buildings and trees.
Provide suitable ground surface to avoid splashing into the gauge.
ii. Setting up
Install the gauge on the foundation. A suggested foundation is detailed
in Diagram 1.
Loosen the three enclosure securing screws and the enclosure.
The gauge is provided with a level. Proceed to level by adjusting the
hold down anchors as required.
Connect lead to the raingauge terminals, in accordance with Diagram
3, and to the recording device, in accordance with manufacturer’s
instruction manual.
V. TEST OPERATION
Manually tip the bucket a number of times, ensuring that each tip is
being recorded and that the tilting mechanism is operating freely.
Replace and secure the enclosure.