Table 1. Parameters
Parameter Description Value and Affect Factory
Default
ACCELERATION DELAY Adjusts truck
acceleration.
0 = short or rapid acceleration
9 = long or slow acceleration
0
DECELERATION DELAY Adjusts truck deceleration
according to throttle
position.
0 = short or rapid deceleration
9 = long or slow deceleration
5
RELEASE BRAKING Adjusts motor braking
strength or regenerative
braking when throttle is
released. This determines
coast distance.
0 = soft braking
9 = strong braking
7
INVERSE BRAKING Adjusts plugging rate. 0 = long or soft plugging
9 = short or rapid plugging
9
CUTBACK SPEED Speed control for trucks in
optional mode.
0 = slow
9 = fast
(not used)
9
MAX SPEED FORW Adjusts maximum speed
in forward direction, forks
trailing.
0 = minimum
9 = maximum
4
MAX SPEED BACK Adjusts maximum speed
in reverse direction, forks
leading.
0 = minimum
9 = maximum
4
LIFT MAX TIME Adjusts the maximum
time for lifting forks.
0 = minimum or approximately
5 seconds
9 = maximum or approximately
65 seconds
9
AUXILIARY TIME Adjusts the maximum
time for auxiliary
hydraulic functions.
0 = minimum or approximately
1.5 seconds
9 = maximum or approximately
6 seconds
5
Programming 2200 SRM 1064