11
Version 17.01, as of: 27-Jun-2017
Figure 4: Layout of the IBC TopFix 200 pitched roof mounting system
Description
L = (MB + 24 mm) × n + 32 mm
Carrier rail length =
(MB + 24 mm) × number of modules per row + 32 mm
MB
Module width
MH
Module height
A
Type TF50+/TF50m/TF60 carrier rail
B
Roof hooks
C
Middle clamp
D
Outside clamp
E
Max. 400mm
X
X selected fixing interval
(dimensioned using PV Manager software)
Z
Max. ¼ of the module height (please observe module
manufacturer specifications)