EasyManua.ls Logo

IBM 5250 - Cabling Types and Rules

IBM 5250
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
,--
Change 5258 Emulation
PCMCIA
Adapter and 5258 Express
PC
Card -
IBM
5258 Express
PC
Card
Configuration
Socket Location: 1
I/0
Port
Address: 2718-271F
Memory
Address:
DC88-DDFF
Interrupt
Level: 5
Controller:
INTEL
82365
Change
PCMCIA
Socket
Location
Change
I/0
Port
Change
Memory
Change
Interrupt
Save
Changes
Esc=Return Fl=Help
F2=Keys
Help F18=Save
Figure
19.
Change 5250 Emulation PCMCJA Adapter Screen
This screen shows the configuration settings that are being used
and lets you change adapter configuration information, including:
PCMCIA socket location
I/O port
Memory address range
Interrupt level
32 5250 Express
Hardware
Manual
2.
Change the socket location, I/O port, memory address range, and
interrupt level settings as needed.
To change the settings, use the arrow keys to highlight the value
that you want and then press Enter. When a range
of
addresses is
needed, select the first address in the range and the program
calculates the end
of
the range.
Note: The full range used is shown on the View Adapter
Configuration screen. For information about viewing the
configuration settings that are being used, see "Viewing the
Adapter Configuration" on page 34.
3.
Do
one
of
the following:
To save your changes, press Y.
To
exit the configuration program without saving your
changes, press N.
When you have configured your adapter, verify that the adapter is
functioning correctly
by
running the offline test using the instructions
in "Testing the Adapter" on page 16.
Changing PCMCIA Controllers
1.
From the Change Adapter Configuration screen, select the
'Change PCMCIA Controller' option. The Change PCMCIA
Controller screen, similar to the one shown in Figure 20 on
page 33, appears. This screen shows the available controllers and
lets you change the controller I/O address and the type.