EasyManua.ls Logo

IBM 88643RU - System x3850 - 8864

IBM 88643RU - System x3850 - 8864
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
000 The server passed the test. Do not replace a CRU or FRU.
195 The Esc key was pressed to end the test. Do not replace a CRU or FRU.
197 This is a warning error, but it does not indicate a hardware failure; do not
replace a CRU or FRU. Take the action indicated in the “Action” column but
do not replace a CRU or a FRU. See the description for Warning in the
section “Diagnostic text messages” on page 112 for more information.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, Type 8864,” on page 23 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only)”, that step must be performed only by a
trained service technician.
Error code Description Action
001-198-000 Test aborted.
1. Check the system-error log and the BMC log for
messages indicating the cause of the error, and
take the indicated action.
2. From the diagnostic programs, run Quick Memory
Test All Banks; then, if an error is detected, take
the indicated action. Make sure you re-enable the
memory in the Configuration/Setup Utility
program. See, “Memory problems” on page 93.
3. Reinstall and, if necessary, update the BIOS code
on the server; then, rerun the test (see “Updating
the firmware” on page 13).
001-250-00x Test failed, where
v x of 0 = ECC logic on I/O board
v x of 1 = ECC logic on memory card
1. Check the system-error log and the BMC log for
messages indicating the cause of the error, and
take the indicated action.
2. From the diagnostic programs, run Quick Memory
Test All Banks; then, if an error is detected, take
the indicated action.
3. From the diagnostic programs, rerun the ECC
test; then, if an error is detected, take the
indicated action.
4. Reseat the following components:
a. Memory card
b. I/O board
5.
Replace the components listed in step 4 one at a
time, in the order shown, restarting the server
each time. Make sure you re-enable the memory
in the Configuration/Setup Utility program. See,
“Memory problems” on page 93
001-292-000 Core system: failed/CMOS checksum failed. Load the BIOS default settings using the
Configuration/Setup Utility program and run the test
again (see “Configuration/Setup Utility menu choices”
on page 15).
001-xxx-000 Failed core tests.
1. Reseat the I/O board.
2. Replace the I/O board.
001-xxx-001 Failed core tests.
1. Reseat the I/O board.
2. Replace the I/O board.
Chapter 5. Diagnostics 113

Table of Contents

Related product manuals