v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, Type 8864,” on page 23 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only)”, that step must be performed only by a
trained service technician.
System-error log message Action
3.3V Power Good Fault
1. Reseat the Remote Supervisor Adapter II SlimLine, if present.
2. Reseat the I/O board.
3. (Trained service technician only) Replace the PCI board.
5V Aux Power Good Fault
1. Reseat the I/O board.
2. (Trained service technician only) Disconnect the cable
connecting the operator information panel to the I/O board.
3. Replace the I/O board.
4. (Trained service technician only) Replace the PCI board.
5V Power Good Fault Disconnect the monitor and all USB devices from the server; then:
1. Reseat the I/O board.
2. Reseat the microprocessor tray.
3. (Trained service technician only) Replace the PCI board.
12V A Bus Fault
1. Reseat the microprocessor tray.
2. Replace the PCI board.
3. Replace the power backplane
12V B Bus Fault
1. Reseat the following components:
a. Disk drives
b. SAS hard disk drive backplane cables
2.
Replace the following components one at a time, in the order
shown, restarting the server each time.
a. Disk drives
b. SAS hard disk drive backplane
c. (Trained service technician only) Power backplane
d. (Trained service technician only) PCI board
12V C Bus Fault
1. Reseat the following components:
a. PCI adapters
b. Microprocessor tray
2.
Replace the following components one at a time, in the order
shown, restarting the server each time.
a. PCI adapters
b. (Trained service technician only) PCI board
c. (Trained service technician only) Power backplane
132 IBM System x3850 Type 8864: Problem Determination and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM 88643RU - System x3850 - 8864 and is the answer not in the manual?

IBM 88643RU - System x3850 - 8864 Specifications

General IconGeneral
BrandIBM
Model88643RU - System x3850 - 8864
CategoryServer
LanguageEnglish

Related product manuals