AS/400
Prompt
AS/400
Parameter
5494
AS/400
Value 5494 Value NotesField Subfield
Station
address
STNADR 2 - - - Values specified in the AS/400
controller description and for the
5494 Remote Control Unit must
match. This value must also be
specified as the last 2 digits of the
AS/400 EXCHID parameter.
Example: Connecting AS/400 to a 5494 controller connected by X.25
Configuration parameters must be coordinated when you connect an AS/400 system to a 5494 controller.
The following diagram shows the AS/400 parameters and 5494 parameters that need to match when you
use X.25.