Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
512E System LIC program exception occurred
The system was inaDIPLmodewhentheproblemwasdetected. A main
storage dump was not taken.
Perform LIC-PIP1.
AJDG301
FI00130
5206 System LIC detected a missing IOP LIC code load
System LIC detected a missing IOP LIC code load during IPL of the IOP.
This indicates that either the IOP code load is not installed on the system
load source device or that system LIC was unable to successfully read that
load from the load source device.
Perform LIC-PIP1.
UG3USR1
5209 System LIC detected an IOP timeout during IOP IPL
Verify that all IOP cable connections are secure, and check tape and other
non-disk devices and media to verify that they are in a ready state.
Perform LIC-PIP1.
UG3USR1
FI00130
AJDG301
5219 System LIC program exception occurred
An IOP signalled to system LIC that it had entered a critical internal state.
LIC automatically attempted to restart the IOP.
This reference code is logged for information only. No action is required.
FI00310
FI00318
FI00065
FI00130
AJDG301
5275 The system issued a reset/reload to the IOP.
System Licensed Internal Code detected that an IOP Reset/Reload has
occurred, and that the IOP sucessfully recovered.
Users who were signed on to a Workstation device under the IOP will need
to sign back on. Any LAN/WAN communications lines under the IOP will
need to be restarted. Tape/Optical devices under the IOP may need to be
varied back on.
To determine the cause of the IOP Reset/Reload, check the Product
Activity Log for additional entries logged with the same System Log ID,
and perform any actions indicated for those errors.
5276 IOP Reset was issued
LIC has detected a problem with the Service Processor IOP and has reset it
but has not initiated reload of the Service Processor.
If the load source is mirrored, some system operations may be able to
continue normally. However, some system service operations have been
suspended and the system should be scheduled for power down as soon as
possible.
Perform a system IPL. If the IPL is successful, then perform LIC-PIP1 to
determine the cause of the problem.
If the system IPL is not successful, perform the action described in the new
SRC.
AJGLD01
AJDG301
FI00021
5310 System LIC program exception occurred
System LIC detected a logical partition configuration data consistency error.
Copy the Product Activity Log data for this error and any related entries
and contact your next level of hardware service support.
LPARSUP
B6xx (including A6xx)
System Reference Codes 273

Table of Contents

Other manuals for IBM iSeries 810

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 810 and is the answer not in the manual?

IBM iSeries 810 Specifications

General IconGeneral
BrandIBM
ModeliSeries 810
CategoryServer
LanguageEnglish

Related product manuals