Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
7102 APPN CP-CP session ended.
7201 A utility failure occurred.
This reference code is for information only. The Uninterruptible Power
System (UPS) is reporting a utility failure.
7202 Utility power restored.
This reference code is for information only. The Uninterruptible Power
System (UPS) is reporting that utility power has been restored.
7203 A battery low condition was detected.
This reference code is for information only. The Uninterruptible Power
System (UPS) is reporting a battery low condition.
7204 Uninterruptible Power System reported a bypass active
This reference code is for information only. The Uninterruptible Power
System (UPS) is reporting a bypass is active.
7205 Battery low condition was reset.
This reference code is for information only. The Uninterruptible Power
System (UPS) is no longer reporting a battery low condition.
7206 UPS reported bypass no longer active
This reference code is for information only. The Uninterruptible Power
System (UPS) is no longer reporting a bypass active condition.
7207 Battery Power Unit needs service
The replacement period for BPU 1, installed in the System Unit, has been
exceeded.
FI00315
7208 Battery Power Unit needs service
The replacement period for BPU 2, installed in the System Unit, has been
exceeded.
FI00315
7209 Battery Power Unit needs service
The replacement period for BPU 1, installed in the Expansion Unit, has
been exceeded.
FI00315
720A Battery Power Unit replacement dates do not match
The replacement dates for one of the Battery Power Units do not match.
Run Display Hardware Configuration and verify that the dates match the
labels on the batteries.
7701 SCSI jumper card was not detected. 21H7625
BACKPLN
7702 Incorrect SCSI jumper card detected 21H7625
7703 System LIC detected a program exception
Storage Management detected a DASD datacheck condition and the
defective sector was reallocated.
Perform a system IPL to restart the system.
7704 General failure detected by HRI component. AJDG301
B6xx (including A6xx)
System Reference Codes 295

Table of Contents

Other manuals for IBM iSeries Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries Series and is the answer not in the manual?

IBM iSeries Series Specifications

General IconGeneral
BrandIBM
ModeliSeries Series
CategoryServer
LanguageEnglish

Related product manuals