Table 11. Definition of status light combinations (continued)
Operation Ready
Fault Single character
display
Response
Input voltage failure Off On 2 Check input power
connections.
Drive firmware
failure
6
Off Flashing
1
3 Update to latest level
firmware.
Drive firmware or
hardware failure
6
Off Flashing
1
4 Clean drive, replace
cartridge, or both, if
needed. Try the
operation again.
Unrecoverable drive
failure
Off Flashing
1
5
Drive or media
failure
7
Off On 6
Media error Off On 7
4
Replace cartridge.
Possible expired
cleaning cartridge.
SAS interface failure Off Flashing
1
8 Check SAS cable and
connector.
Recoverable drive
error
8
Off On A Clean drive and try
the operation again.
Incorrect media Off On J Insert correct media
type.
Firmware update is in
progress
Both LEDs flashing
together
Both LEDs flashing
together
Off Wait for update to
complete.
Incorrect firmware
update tape used
Off On F
4
Replace firmware
update tape.
Firmware update
failed
9
Off Flashing
1
H Try the firmware
update operation
again.
Write operation was
attempted and media
is write-protected
Off On P
4
Use media that is not
write protected.
Drive is in service
mode
Flashing rapidly
1
On On
10
Self-test is in progress Flashing
1
On The number 1 is
flashing
Wait for test to
complete
12 Managing devices

Table of Contents

Other manuals for IBM Power 750 Express

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power 750 Express and is the answer not in the manual?

IBM Power 750 Express Specifications

General IconGeneral
BrandIBM
ModelPower 750 Express
CategoryServer
LanguageEnglish

Related product manuals