7. Power on the server using the ASMI by completing the following steps:
a. In the navigation area, click Operations > Server power operations. The power state of the
system is displayed.
b. Under Operations, ensure that you have selected the PHYP standby system server rmware boot
option and click Power on.
Note: During the IPL, the system displays C6004031 on the control panel, which indicates that the
system is searching for an Operations Console. The system might take 20 - 30 minutes to complete
this action. If A6005008 is displayed on the control panel, this means that no Operations Console
is available. This might indicate that the system is not preinstalled with IBM i and you must set the
console type to LAN.
8. Perform this step if the system is not preinstalled with IBM i.
To install IBM i on the server, complete the following steps:
a. Load the installation media.
b. In the navigation area, click Operations > Server power operations
c. Set the Server rmware start policy to Standby and power on the system.
d. Set the IBMi partition boot mode to D.
e. Set the IBMi load source to the target load source slot.
f. Set the IBMi alternate restart device to the slot containing the installation media.
g. Set the IBMi console to the target Ethernet slot.
h. Save the settings and press Continue to OS Running.
To set the console type to LAN, complete the following steps:
a. Use the enterprise baseboard management controller (eBMC) to set the location of the Ethernet
card that the LAN console will use. In the eBMC interface, select Server Power Operations >
Settings > IBMi console.
b. The console type defaults to LAN.
9. Connect the Operations Console by completing the following steps:
a. Open IBM i Access Client Solutions (ACS).
b. Under Management, click System Congurations.
c. Select Locate Console.
d. Click Search. After a few seconds, a connection displays. Click the connection and then click
Console.
e. In the Pending Authorization window, type the User ID and Password.
f. Accept the security certicate. Ensure that you accept it, otherwise your connection will not
continue. A console window opens. If the window is blank at rst but the cursor is in the upper
left corner, it means that the screen is waiting for the media to provide the information to be
displayed.
10. To set a static IP address for the Operations Console, complete the following steps:
a. Sign on with QSECOFR. The default password is QSECOFR, and it is case-sensitive.
b. At the DST Main Menu b, select Option 3- Use Dedicated Service Tools.
c. Select Option 5- Work with DST environment.
d. Select Option 2- System Devices.
e. Select Option 7- Congure service tools LAN adapter.
f. Type the IP settings that you want to use. Optional: For the host name for Service Tools, you can
type a host name if it is also registered in your network DNS. It is recommended that you type the
word Default and enter the IP address that you want to use.
g. Press F7 to store the information.
24
Power Systems: Installing the IBM Power S1012 (9028-21B)