Table 90. Electrical
1
(continued)
Electrical characteristics Properties
Maximum measured power 523 W
Minimum kVA 0.106
Maximum kVA 0.352
Minimum thermal output 630 BTU/hr
Maximum thermal output 1784 BTU/hr
Input voltage (low range) 100 - 127 V ac
Input voltage (high range) 200 - 240 V ac
Frequency (low range) 47 Hz to 53 Hz
Frequency (high range) 57 Hz to 63 Hz
1. Power consumption and heat output vary depending on the number and type of optional features that are
installed and the power-management optional features that are in use.
Table 91. Environmental requirements
Environment Allowable operating Nonoperating Nonoperating (shipping)
Temperature 10°C - 32°C (50°F - 89.6°F) -40°C to 60°C (-40°F to
140°F)
Humidity range 8% - 80% 8% - 80%
Maximum dew point 24°C (75°F) 27°C (80.6°F) 29°C (84.2°F)
Maximum altitude 2133 m (7000 ft) (Server off)
Table 92. Noise emissions
1
Product description
Declared A-weighted sound power level,
L
WAd
(bels)
Declared A-weighted sound pressure level,
L
pAm
(dB)
One hard disk drive
configuration
Operating Nonoperating Operating Nonoperating
5.2 4.8 37 33
Note:
1. These levels were measured in controlled acoustical environments according to the procedures specified by the
American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with IS) 9296.
Actual sound-pressure levels in a given location might exceed the average values stated because of room
reflections and other nearby noise sources. The declared sound-power levels indicate an upper limit, below
which a large number of computers will operate.
7042-C08 Hardware Management Console specifications
Hardware specifications for model 7042-C08 provide detailed information for your Hardware
Management Console (HMC), including dimensions, electrical, power, temperature, and environmental
specifications.
The HMC controls managed systems, including the management of logical partitions and the use of
capacity on demand. Using service applications, the HMC communicates with managed systems to
detect, consolidate, and send information to IBM for analysis. The HMC provides service technicians with
diagnostic information for systems that can operate in a multiple-partitioned environment.
Use the following specifications to plan for your HMC.
Site and hardware planning 77

Table of Contents

Other manuals for IBM Power Systems 8202-E4B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power Systems 8202-E4B and is the answer not in the manual?

IBM Power Systems 8202-E4B Specifications

General IconGeneral
BrandIBM
ModelPower Systems 8202-E4B
CategoryServer
LanguageEnglish

Related product manuals