Line
Polarity
With
both
lines
tied
to
the
shield
at
the
far
end,
measure
(at
the
nearest
end):
Conductor-to-conductor: Less
than
110 ohms
4
Each
conductor
to
shield: Less
than
70
ohms
4
A
reading
greater
than
110
or
70
ohms, respectively,
means
there
is
an
open
circuit.
After
testing
the
line
continuity
and
making
any
necessary
corrections,
check
the
polarity
as follows.
With
conductor
A
of
the
cable plug
tied
to
the
shield
at
the
far
end,
measure
(at
the
nearest
end) from
conductor
A
to
the
shield.
This
should
be
less
than
70
ohms;
if
it
is
over
70
ohms,
lines
are
crossed.
Widest Notch R9476037·2
The
polarity
of
the
line
must
be
maintained
for
each
cable
segment
and
for
the
entire
cable
run
to
ensure
proper
machine
operation.
4 Values for
shorter
length
are
proportional because
this
is a
linear
function.
For
example, a cable
with
half
the
maximum
length
would
have
half
the
resistance.
Appendix A.
Bulk
Cable Information
41