2803
TAPE
CONTROL
(Continued)
Deloy Counter
Milliseconds
240/1/2/3/4
Model I
Logic Page
Function Reference
9-Track
~
End
WDO
70.31. 1
Reset
Go
on
See
Note
2
Check
Chor
{ms)
Check
Chor
(ms)
Write
040
or
53
MS
Not
LP
70.31.1
End
WD
Not
Rise
of
Go
11.7-16.0
11.7-16.0
LP
70.71.1
Dl60TA
70.41.
1
Set
Go
in
Foll
of
Ml
25.5-26.5
25.5-26.5
Bkwd
Rev
Dfy
70.71, I
096
TA
70.41.
l
Set
Bkwd
+MS
Control 37.
4-40.2
37.4-40.2
Read
or Write
7V.61.1
End
Read
Deloy
70.41.
I
End
RD
Not
Rise
of
Go
6.8
-
7.6
12.4-13.2
LP
RDl7-RD31
70.71.
l
End
RD
Bkwd
Rire
of
Go
2.0
-
2.8
2.0
-
2.8
RDS
70.71.1
End
RD
LP
Rise
of
Go
41.1-42.0
41.1-42.0
RD
103
70.71.
I
Bksp
Reset
RD
Cond
70.21.
l
Reset Read
+ROD
5.6
-
6.4
9.6
-10.4
Cond &
Go
RDDl
4-RDD24
70.61.1
WD
320
70.42.
l
End WO
LP
Rise
of
Go
85.9-86.
8
85.9-86.8
WD
215
70.71.1
WD
17
70.81.
l
Set
Read
Rise
of
Go
6.8
-
7.6
6.8-7.6
Cond
on
Write
Model 2
End
WDD
70.31.
I
Reset
Go
on See
Note
2
Check Char
(ms)
Check Char
{ms)
Write
D40
or 53
MS
Not
LP
70.31.1
End
WD
Not
Rise
of
Go
6.3
-
6.8
6.3
-
6.8
LP
70.70.1
Dl60
TA
70.41.1
Set
Go
In
Rise
of
TA
30.4-32.4
30.4-32
.4
70.65.
J
D96
TA
70.41
.1
Set
Bkwd
Rise
of
TA
19.1-19.6
19.
f-19.6
Read
or Write
70.65.1
End
Read
Deloy
70.41.
l
End
RD
Not
Rise
of
Go
3.4-3.8
5.9
-
6.6
LP
70.71.
lp
End
RD
Bkwd
Rise
of
Go
1.6
-
2.0
l.6
-
2.0
RDS
70,71.
I
End
RD
LP
Rise
of
Go
20.5-21.0
20.5-21.
0
RD103
70.71.1
Bksp
Reset
Read
Cond
70.21.
I
Reset
Read
+ROD
2.2
-
2.6
4.2-
4.6
Cond &
Go
RDDJ1-RDD21
70.61.1
WD
215 + 320
70.42.
l
End
WO
LP
Rise
of
Go
43.l}-43.4
43.0-43.4
WD
215
70.71.
l
WD
17
70,81.1
Set
Read
Rise
of
Go
3.4
-
3.8
3.4
-
3.8
Condon
70.71.1
Write
Mo~el
3
End
WOO
70.31.
J
Reset
Go
on
+MS
Control See
Note
1
1.7
- 2
'.}
Write
70.61.
1
030+32+53MS
70.31.
l
End
WO
not
Rise
of
Go
5.3
-
5.5
5.3
-
5.5
Not
LP
LP
70.71.
l
0160
TA
70.41.
I
Set
Go
in
+MS
Control
16.0-16.2
16.0-16.2
70.42.1
Bkwd
70.61.
l
096
TA
70,41.1
Set
Bkwd
+MS
Control
9.5
-
9.8
9.5
-
9,8
70.42.
J
Read or Write
70.61.
l
End
Read
Deloy
70.41.
l
End
RD
not
Rise
of
Go
1.5
-
1.7
2.8-3.0
RDJ5-RD28
70.71.
1
End
RD
Bkwd
Rise
of
Go
1.2
- J
.4
1.2
-
1.4
RD12
70.71.
l
End
RD
LP
Rise
of
Go
15.9-16.2 15.9-16.2
70.71
.1
Bksp
Reset
Read
Cond
70.21.
l
Reset
RD
+ROD
.69-
.90
1.9
- 2.1
Cond
70.61
.1
WO
215 + 320
70.42.
l
End
WD
LP
Rise
of
Go
31.9-32.2
31.
9-32
.2
70.71.
1
WD
32
70,81
.1
Set
Read
Rise
of
Go
3.2
-
3.4
3.2
-
3.4
Condon
Write
NOTE
l:
End
WDD
for
9-Trock Mod
3 occurs
at
WDD
403
NOTE 2:
WDD
ends with
the
reset
of
write trigger release.
Go
foils with the set
of
1st
check
char with Mod l
or
Mod
2.
88
S/360
IBM
CONFIDENTIAL