The pump works
but does not
feed water
Pressure stub pipe of the pump
or the pressure pipeline (hose) is
blocked
Too large resistance at the
flow through the pressure
pipeline (hose).
Not enough water in the pumping
well
The pump does not
shut down in spite
of pumping out the
water
The float switch is suspended
on the tank wall or on the
pressure pipeline (hose)
The float switch is blocked in"on"
position
Operation of the
pump interrupted.
Thermal switch
installed inside the
pump interrupts
the supply of
power.
The pump is not completely
submerged in water
Temperature of the pumped
water is too high.
The pump often
turns on and off
Return valve not installed on the
pressure stub pipe. When the
pump pumps out water to the level
at which the float switch turns off
the pump, water from the pressure
pipeline (hose) flows back to the
well. After flowing in the sufficient
quantity of water, the float switch
turns on the pump. The cycle is
constantly repeated