Brushless Motor Driver SEH400RB
4.2 Terminal Description
4.3 Description of external control signal circuit
The F/R and EN terminals are as below
,
amplitude ranges less than 0.5V, or higher than 2.5VDC
External potentiometer speed regulation
If EN and GNDE connect, the motor runs;
If EN and GNDE disconnect, the motor stops. (They disconnect
by default.)
If F/ and GNDE connect, the motor runs anti-clockwise
If F/ and GNDE disconnect, the motor runs clockwise
Control signal common ground port
Under port control mode P-03-4, BRK connects with GNDE, the
motor brake stops
Frequency output.
The relationship between the frequency detected and the speed is:
N(rpm)= F
F: Output pulse frequency(Hz) N: Motor speed
For example:F=500Hz, then N(rpm)=500
(Note: Motor poles should be set right)
It is a high resistance output, and when a fault occurs, it outputs a
low level