07
Error Codes & Solutions
4
Error Code
The cooling fan overloads with more
than 1 A of current.
E2
Motor start error
The motor of compressor is blocked or
the pressure difference in the refrigeration
system is too high.
E3
Minimum motor speed error
The compressor overloads and the
motor can not maintain its minimun speed
1850 rpms.
E4
Thermal cut-out of electronic unit
Thermal cut-out error If the refrigeration
system overloads, or the ambient
temperature is too high, the thermal sensor
is overheated.
E5
The DC voltage is below the protection
setting and the battery protection mode is
activated.
E1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Iceco VL45 and is the answer not in the manual?

Iceco VL45 Specifications

General IconGeneral
Capacity45 liters
Power Source12/24V DC, 110-240V AC
RefrigerantR134a
Power Consumption45W
Cooling SystemCompressor
MaterialPlastic and metal