iCharger Synchronous Balance Charger/Discharger 3010B
LiPo Termination
Voltage 4.20V
LiFe Termination
Voltage 3.60V
Delay 0min
Lilo Termination
Voltage 4.10V
-
Dec
+
Inc
-
Dec
+
Inc
-
Dec
+
Inc
Pb Termination
Voltage 2.40V
-
Dec
+
Inc
Inc
Dec
Inc
Dec
Inc
Dec
Termination voltage for LiFe. Adjust LiFes charge termination voltage.
Press Start/Enter for more than 3 seconds to blink the Voltage value,
then press Dec and Inc to adjust the termination voltage.
Range: 3.40V 3.90V, Step: 0.01V (3.60V, default)
Termination voltage for Lilo. Adjust Lilos charge termination voltage.
Press Start/Enter for more than 3 seconds to blink the Voltage value,
then press Dec and Inc to adjust the termination voltage.
Range: 3.90V 4.20V, Step: 0.01V (4.10V, default)
Termination voltage for LiPo. Adjust LiPos charge termination voltage.
Press Start/Enter for more than 3 seconds to blink the Voltage value,
then press Dec and Inc to adjust the termination voltage.
Range: 4.00V 4.30V, Step: 0.01V (4.20V, default)
Termination voltage for Pb. Adjust Pbs charge termination voltage. Press
Start/Enter for more than 3 seconds to blink the Voltage value, then
press Dec and Inc to adjust the termination voltage.
Range: 2.20V 2.50V, Step: 0.01V (2.40V, default)
Note: The Termination voltage controls the transition from Constant
Current (CC) to Constant Voltage (CV) charging for LiXx and Pb
chemistries. It also defines the per-cell limit for cell overvoltage detection.
If you change the default termination voltage, the charge and discharge
setting screen will note this difference by alternatively blinking batterys
type and setting voltage value.