• UT-115 SPECIFICATIONS
M GENERAL
Usable temperature range : 10˚C to +60˚C; +14˚F to +140˚F
Power supply requirement : 5.0 V DC
(4.5 V8.5 V for AMBE IC VCC line)
AF input level : 1 V
p-p typical
Modulation output level : 350 mV
p-p typical
Demodulation input level : 500 mV
p-p typical
AF output level : 750 mV
p-p typical
CODEC type : AMBE
Transfer speed : 4.8 kbps
Control signal input voltage : 3.0 V5.0 V for High
0 V for Low
Control signal output voltage : Open collector for High
0 V for Low
Current drain (at 5.0 V DC) : 55 mA typical
Dimentions : 30(W)×38(D) mm;
(projections not included) 1
3
16(W)×1
1
2(D) inch
Weight : Approx. 6 g;
7
32 oz
(accessoreis not included)
Connector : AXN430C330
All stated specifications are subject to change without notice or obligation.

Other manuals for Icom IC-2200H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-2200H and is the answer not in the manual?

Icom IC-2200H Specifications

General IconGeneral
Frequency Range144-148 MHz
ModeFM
Antenna ConnectorSO-239
Weight1.2 kg
Power Supply Requirement13.8 V DC
Dimensions140 x 40 x 160 mm
Current Consumption15A (at 65W output)
Number of Channels207 (200 regular, 6 scan edges, 1 call)