4 - 13
4-6 METER ADJUSTMENTS
ADJUSTMENT ADJUSTMENT CONDITION DISPLAY
OPERATION
ENTERING
ADJUSTMENT
MODE
1 • Enter the adjustment mode:
q Turn power OFF.
w
Terminate the [REMOTE] jack
with a 3.5(d) mm mini-plug.
e
While pushing [SSB] and [CW/
RTTY], turn power ON.
ADJUST MODE
Push [F-1 (METER)], [F-2 (TX)] or [F-3 (RX)] to
select each adjustment mode.
Once entering adjustment mode, use [F-1
(
)] to skip items, or [F-2 (EXIT)] to return the
opening display.
CAUTION:
NEVER
select adjustment items [F-2 (TX)] while transceiver is connected to an SSG. Because transceiver auto-
matically transmits when transmit item in the [F-2 (TX)] is selected.
METER
SCALE
1• Push [F-1 (METER)] to enter the
meter scale adjustment.
-- METER --
SCALE S1
Set the analog meter to S1 position using the
tuning dial. Then push [F-5 (SET)] to store the
“S1” meter into memory, and go to the next step.
2
-- METER --
SCALE S3
Set the analog meter to S3 position using the
tuning dial. Then push [F-5 (SET)] to store the
“S3” meter into memory, and go to the next step.
3
-- METER --
SCALE S5
Set the analog meter to S5 position using the
tuning dial. Then push [F-5 (SET)] to store the
“S5” meter into memory, and go to the next step.
4
-- METER --
SCALE S7
Set the analog meter to S7 position using the
tuning dial. Then push [F-5 (SET)] to store the
“S7” meter into memory, and go to the next step.
5
-- METER --
SCALE S9
Set the analog meter to S9 position using the
tuning dial. Then push [F-5 (SET)] to store the
“S9” meter into memory, and go to the next step.
6
-- METER --
POWER S+20
Set the analog meter to S9+20 position using
the tuning dial. Then push [F-5 (SET)] to store
the “S9+20” meter into memory, and go to the
next step.
7
-- METER --
POWER S9+40
Set the analog meter to S9+40 position using
the tuning dial. Then push [F-5 (SET)] to store
the “S9+40” meter into memory, and go to the
next step.
8
-- METER --
SCALE S9+60
Set the analog meter to S9+60 position using
the tuning dial. Then push [F-5 (SET)] to store
the “S9+60” meter into memory, and retuns to
the opening display.
TX METER
(HF POWER
METER)
1
Push [F-2 (METER)] to enter the TX
meter scale adjustment.
Connect an RF power to [ANT1]
connector.
Connect a 100
dummy load to
[ANT2] connector.
Connect audio generator to [MIC]
connector and set as:
FREQUENCY : 1.5 kHz
LEVEL : 10mVrms
-- TX --
POWER 0%
Push [F-5 (SET)] to store the “POWER 0%”
meter into memory, and go to the next step.
2
-- TX --
POWER HF Tuner
Set the output power to 10 W using the tun-
ing dial. Then push [F-5 (SET)] to store the
“POWER HF Tuner” meter into memory, and
go to the next step.
3
-- TX --
POWER HF 10%
Set the output power to 10 W using the tun-
ing dial. Then push [F-5 (SET)] to store the
“POWER HF 10%” meter into memory, and go
to the next step.
4
-- TX --
POWER HF 25%
Set the output power to 25 W using the tun-
ing dial. Then push [F-5 (SET)] to store the
“POWER HF 25%” meter into memory, and go
to the next step.
5
-- TX --
POWER HF 50%
Set the output power to 50 W using the tun-
ing dial. Then push [F-5 (SET)] to store the
“POWER HF 50%” meter into memory, and go
to the next step.
6
-- TX --
POWER HF 100%
Set the output power to 104 W using the tun-
ing dial. Then push [F-5 (SET)] to store the
“POWER HF 100%” meter into memory, and
go to the next step.