IC-756PRO Alignment Procedure
PLL Board
Reference Oscillator
- Connect Frequency counter to P81 on the PLL board
- Adjust L53 and R33 for 64.000000MHz
- Connect RF volt meter to P81 on the PLL board
- Adjust L81 and L82 for maximum level
-
LPL A
- Set display to 0.0300000MHz, LSB
- Connect multi-meter to check point LPA
- Adjust C154 for 2.0V
VCO A
- Connect multi-meter to check point LVA
- Set display to 7.999999MHz, USB
- Adjust C278 for 4.3V
- Set display to 19.999999MHz, USB
- Adjust C258 for 4.3V
- Set display to 44.999999MHz, USB
- Adjust C228 for 4.3V
- Set display to 60.000000MHz, USB
- Adjust C208 for 4.3V

Other manuals for Icom IC-756PRO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-756PRO and is the answer not in the manual?

Icom IC-756PRO Specifications

General IconGeneral
TypeHF/50MHz Transceiver
Supply Voltage13.8 V DC
Receiver TypeTriple conversion superheterodyne
Frequency Range0.03-60 MHz
ModesSSB, CW, AM, FM, RTTY
Selectivity2.4 kHz (SSB), 6 kHz (AM)
Image Rejection70 dB
Current Drain20 A (max)
Intermediate Frequencies455 kHz