5 - 10
5-4 RECEIVE ADJUSTMENT
5-4-1 RECEIVE ADJUSTMENT FOR OTHER THAN IC-F26-L
1) Select an adjustment item using cursor or [
] / [
] keys of the PC’s keyboard.
2) Set or modify the adjustment value as specifi ed using [
] / [
] keys of the PC’s keyboard, then push the [ENTER] key.
ADJUSTMENT ADJUSTMENT CONDITION OPERATION
ADJUSTMENT
ITEM
VALUE
RECEIVE
SENSITIVITY
-Preparation-
1
<For IC-F24S/F25S/F26S only>
Clone the "ADJ CH RX.icf" into the transceiver.
Connect an SSG to the
antenna connector.
• Set the SSG as;
Frequency : 400.1000 MHz
[Low band]
450.1000 MHz
[High band]
Level : +20 dB
μ
Modulation : 1 kHz
Deviation : 3.5 kHz
––
-Adjustment- 2 • CH. (16CH/2CH) :
CH.12/CH.1
• Receiving
1) Select the item [BPF (T1)], then
push the [ENTER] key.
2) Select the item [BPF (T2)], then
push the [ENTER] key.
[BPF (T1)]
[BPF (T2)]
(Automatic
adjustment)
CONVINIENT: [BPF (T1)] and [BPF (T2)] can be adjusted at same time as below.
2 • CH. (16CH/2CH) :
CH.11/CH.1
• Receiving
Select the item [BPF ALL], then
push the [ENTER] key.
[BPF ALL]
(Automatic
adjustment)
SQUELCH
-Preparation-
1
<For IC-F24S/F25S/F26S only>
Clone the "ADJ CH RX.icf" into the transceiver.
Connect an SSG to the
antenna connector.
• Set the SSG as;
Frequency : 400.1000 MHz
[Low band]
450.1000 MHz
[High band]
Level : –14 dB
μ
Modulation : 1 kHz
Deviation : 3.5 kHz
––
-Adjustment- 2 • CH. (16CH/2CH) :
CH.12/CH.1
• Receiving
1)
Decrease the adjustment value
[SQL] to close the squelch once,
then increase the value to open the
squelch.
2) Select the item [SQL], then push
the [ENTER] key to store the adjust
value.
[SQL]
(Automatic
adjustment)