6 - 6
6-4 RECEIVE ADJUSTMENT
Select an adjustment item using [
] / [
] keys, then set to the specifi ed value using [
] / [
] keys on the connected PC’s keyboard.
ADJUSTMENT ADJUSTMENT CONDITION UNIT LOCATION VALUE
RECEIVE
SENSITIVITY
[BPF (T1)]
[BPF (T2)]
NOTE:
“RECEIVE SENSITIVITY” must be adjusted before “S-METER. Otherwise, “S-METER” will not be
adjusted properly.
1
• Channel : CH 8
Connect the SSG to the antenna connec-
tor and set as;
Frequency : 400.00 MHz (Low)
: 450.00 MHz (High)
Level : +20 dBµ
(–87 dBm)
Modulation : 1 kHz
Deviation : ±3.5 kHz
• Receiving
SP jack Connect the SINAD meter
with an 4
load to the SP
jack.
Minimum distortion
level
CONVENIENT:
The “RECEIVE SENSITIVITY” can be adjusted automatically.
1: Put the cursor on “BPF C ALL” and push [ENTER] key.
2: The connected PC tunes BPF’s to peak levels automaticaly.
S-METER
(S3 level)
[RSSI S3 level]
1
• Channel : CH 8
Connect the SSG to the antenna connec-
tor and set as;
Frequency : 400.00 MHz (Low)
: 450.00 MHz (High)
Level : +23 dBµ
(–84 dBm)
Modulation : 1 kHz
Deviation :
±
3.5 kHz
• Receiving
Push the [ENTER] key on the connected PC’s keyboard to set
“S3” level.
[RSSI S1 level]
(S1 level)
2
Set the SSG as;
Level : –7 dBµ
(–114 dBm)
• Receiving
Push the [ENTER] key again to set “S1” level.
SQUELCH
[SQL]
1 • Channel : CH 3
• Set the Squelch Level “2.
• Close the squelch by adjusting the value of
[SQL] item on the CS-F5060 ADJ’s screen.
Connect the SSG to the antenna connec-
tor and set as;
Frequency : 400.00 MHz (Low)
: 450.00 MHz (High)
Level : –14 dBµ
(–121 dBm)
Modulation : 1 kHz
Deviation :
±
3.5 kHz
• Receiving
SP jack Connect an 4
speaker to
the SP jack.
Close the squelch by
increase the value of
[SQL].
Set the [SQL] to the
value that the audio
signals just appears.
; The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.