EasyManua.ls Logo

ICP F9MVE0801716A2 User Manual

ICP F9MVE0801716A2
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Printed in U.S.A. 440 04 4801 00 7/3/2014
SERVICE AND TECHNICAL
SUPPORT MANUAL
TwoStage, Variable Speed ECM Blower Motor
35” Tall, High Efficiency Condensing Gas Furnace
(F/G)9MVE ’A2’ Series
Save this manual for future reference.
Safety Labeling and Signal Words
DANGER, WARNING, CAUTION, and NOTE
The signal words DANGER, WARNING,
CAUTION, and NOTE are used to identify levels of
hazard seriousness. The signal word DANGER is
only used on product labels to signify an immediate
hazard. The signal words WARNING, CAUTION,
and NOTE will be used on product labels and
throughout this manual and other manual that may
apply to the product.
DANGER Immediate hazards which will result in
severe personal injury or death.
WARNING Hazards or unsafe practices which
could result in severe personal injury or death.
CAUTION Hazards or unsafe practices which
may result in minor personal injury or product or
property damage.
NOTE Used to highlight suggestions which will
result in enhanced installation, reliability, or
operation.
!
WARNING
Signal Words in Manuals
The signal word CAUTION is used throughout
this manual in the following manner:
!
CAUTION
Signal Words on Product Labeling
Signal words are used in combination with
colors and/or pictures or product labels.
The signal word WARNING is used throughout
this manual in the following manner:
Safetyalert symbol
When you see this symbol on the unit and in
instructions or manuals, be alert to the
potential for personal injury.
TABLE OF CONTENTS
STARTUP, ADJUSTMENT, AND SAFETY CHECK 4...........
SETUP SWITCHES 4......................................
PRIME CONDENSATE TRAP WITH WATER 4.................
PURGE GAS LINES 5......................................
ADJUSTMENTS 5.........................................
ADJUST TEMPERATURE RISE 11............................
ADJUST BLOWER OFF DELAY (HEAT MODE) 12..............
ADJUST COOLING AIRFLOW 12.............................
ADJUST CONTINUOUS FAN AIRFLOW 12....................
ADJUST THERMOSTAT HEAT ANTICIPATOR 14...............
CHECK SAFETY CONTROLS 14.............................
CHECKLIST 14.............................................
COOLING AND HEATING AIR DELIVERY - CFM 15.............
SERVICE AND MAINTENANCE PROCEDURES 17.............
ELECTRICAL CONTROLS AND WIRING 17...................
CLEANING AND/OR REPLACING AIR FILTER 19..............
BLOWER MOTOR AND WHEEL MAINTENANCE 20............
CLEANING BURNERS AND FLAME SENSOR 21...............
SERVICING HOT SURFACE IGNITER 22......................
FLUSHING COLLECTOR BOX AND DRAINAGE SYSTEM 23....
CLEANING CONDENSATE DRAIN AND TRAP 23..............
CLEANING HEAT EXCHANGERS 23..........................
SERVICE LABEL 26.........................................
WIRING DIAGRAM 27.......................................
TROUBLESHOOTING GUIDE FLOW CHART 28..............
SEQUENCE OF OPERATION 30.............................
PARTS REPLACEMENT INFORMATION GUIDE 35.............
PRODUCT NOMENCLATURE 36.............................
MODELS
(F/G)9MVE0401410A2
(F/G)9MVE0401712A2
(F/G)9MVE0601412A2
(F/G)9MVE0601714A2
(F/G)9MVE0801716A2
(F/G)9MVE0802120A2
(F/G)9MVE1002120A2
(F/G)9MVE1202422A2
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program.
For verification of certification for individual
products, go to www.ahridirectory.org .
Question and Answer IconNeed help?

Do you have a question about the ICP F9MVE0801716A2 and is the answer not in the manual?

ICP F9MVE0801716A2 Specifications

General IconGeneral
BrandICP
ModelF9MVE0801716A2
CategoryFurnace
LanguageEnglish

Summary

Safety Labeling and Signal Words

Signal Words in Manuals

Details the usage of DANGER, WARNING, CAUTION, and NOTE signal words within the manual.

Signal Words on Product Labeling

Describes the use of signal words in combination with colors, pictures, or labels on the product.

Start-Up, Adjustment, and Safety Check

General Setup Requirements

Covers essential electrical and installation requirements before startup.

Configuration via Setup Switches

Explains how to configure furnace operation using DIP switches for various applications.

Manifold Pressure Adjustment

Details procedures for setting gas manifold pressure to achieve correct input rates.

Airflow and Temperature Rise Adjustments

Guides on adjusting blower speed for optimal heating and cooling performance.

Safety Control Verification

Outlines tests to verify the proper function of safety devices like limit switches.

Service and Maintenance Procedures

Electrical Controls and Wiring Overview

Details furnace wiring diagrams and electrical control system information.

Troubleshooting Guide

Introduces diagnostic tools like flow charts for issue isolation.

Blower Motor and Wheel Maintenance

Procedures for cleaning and servicing the blower motor and wheel.

Burner and Flame Sensor Cleaning

Instructions for cleaning combustion components like burners and flame sensor.

Heat Exchanger Cleaning and Winterization

Procedures for cleaning heat exchangers and preparing for cold weather.

Sequence of Operation

Two-Stage Heating Modes

Describes furnace operation with single and two-stage thermostats for heating.

Cooling and Dehumidify Modes

Details furnace operation during cooling and dehumidification cycles.

Continuous Blower Operation

Outlines how the blower operates in continuous fan mode.

Parts Replacement Information Guide

Product Nomenclature Explanation

Explains how to decode the furnace model number based on digit positions.