These instructions must be read and understood completely before attempting installation.
Safety Labeling and Signal Words
DANGER, WARNING, CAUTION, and NOTE
The signal words DANGER, WARNING,
CAUTION, and NOTE are used to identify levels of
hazard seriousness. The signal word DANGER is
only used on product labels to signify an immediate
hazard. The signal words WARNING, CAUTION,
and NOTE will be used on product labels and
throughout this manual and other manual that may
apply to the product.
DANGER - Immediate hazards which will result in
severe personal injury or death.
Signal Words in Manuals
The signal word WARNING is used throughout
this manual in the following manner:
The signal word CAUTION is used throughout
this manual in the following manner:
WARNING - Hazards or unsafe practices which
could result in severe personal injury or death.
CAUTION - Hazards or unsafe practices which
may result in minor personal injury or product or
property damage.
NOTE - Used to highlight suggestions which will
result in enhanced installation, reliability, or
operation.
TABLE OF CONTENTS
Signal Words on Product Labeling
Signal words are used in combination with
colors and/or pictures or product labels.
Zt& Safety-alert symbol
When you see this symbol on the unit and in
instructions or manuals, be alert to the
potential for personal injury.
SAFETY CONSIDERATIONS .............................. 3
INTRODUCTION ......................................... 4
CODES AND STANDARDS ................................ 4
ELECTROSTATIC DISCHARGE (ESD) ..................... 5
DIMENSIONS ........................................... 6
LOCATION RELATIVE TO COOLING EQUIPMENT ........... 8
AIR FOR COMBUSTION AND VENTILATION ................ 9
CONDENSATE TRAP .................................... 12
INSTALLATION .......................................... 19
UPFLOW INSTALLATION ................................. 19
DOWNFLOW INSTALLATION .............................. 20
HORIZONTAL INSTALLATION ............................. 21
AIR DUCTS ............................................. 27
GAS PIPING ............................................. 27
ELECTRICAL CONNECTIONS ............................. 29
J-BOX INSTALLATION ................................... 31
VENTING ............................................... 36
SPECIAL VENTING REQUIREMENTS FOR
INSTALLATIONS IN CANADA ............................. 36
DIRECT VENT / 2-PIPE SYSTEM .......................... 40
VENTILATED COMBUSTION AIR .......................... 4t
TERMINATION REQUIREMENTS FOR THE PROVINCES
OF ALBERTA AND SASKATCHEWAN ...................... 4t
INSTALLING THE VENT TERMINATION .................... 50
MAXIMUM EQUIVALENT VENT LENTH ..................... 55
MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS ........ 58
(SO9001)
Use of the AHR( Certified TM Mark indicates a
manufacturer's participation in the program.
For verification of certification for individual
products, go to www.ahridirectory.org .
INSTALLER: Affix these instructions on or adjacent to the
furnace.
CONSUMER: Retain these instructions for future
reference.
Portions of the text and tables are reprinted from NFPA 54/ANS( Z223.1-2009_<;P, with permission of National Fire Protection Association, Quincy, MA 02269 and American Gas Association, Washington, DC
20001. This reprinted material is not the complete and official position of the NFPA or ANSI, on the referenced subject, which is represented only by the standard in its entirety.
PrintedinU.S.A. 440 01 4001 04 July2012
Question and Answer IconNeed help?

Do you have a question about the ICP F9MXT and is the answer not in the manual?

ICP F9MXT Specifications

General IconGeneral
BrandICP
ModelF9MXT
CategoryFurnace
Efficiency96% AFUE
StagesTwo-Stage
Warranty10-Year Parts Limited Warranty
TypeGas
Heating Capacity40, 000-120, 000 BTU/h
Blower TypeVariable Speed

Summary

Safety Labeling and Signal Words

Required Notice for Massachusetts Installations

Manufacturer Requirements - Gas Equipment Venting System Provided

Details manufacturer requirements for gas equipment venting systems.

Manufacturer Requirements - Gas Equipment Venting System Not Provided

Details manufacturer requirements when venting systems are not provided.

Safety Considerations

WARNING Fire, Explosion, Electrical Shock, and Carbon Monoxide Poisoning Hazard

Warns about hazards from improper installation, alteration, or service.

Codes and Standards

Combustion and Ventilation Air

Gas Piping and Gas Pipe Pressure Testing

Electrical Connections

Electrostatic Discharge (ESD) Precautions Procedure

CAUTION Furnace Reliability Hazard

Cautions about electrostatic discharge damaging electronic components.

Location

CAUTION Personal Injury and/or Property Damage Hazard

Warns about hazards from improper use or installation leading to premature failure.

WARNING Carbon Monoxide Poisoning / Component Damage Hazard

Warns about corrosive air causing component failure and CO poisoning.

Prohibit Installations

WARNING Fire, Injury or Death Hazard

Warns about hazards when installing in garages or hazardous atmospheres.

WARNING Fire Hazard

Warns against installing furnace on its back or hanging it downward.

Air for Combustion and Ventilation

CAUTION Furnace Corrosion Hazard

Cautions about furnace damage from contaminated combustion air.

Indoor Combustion Air NFPA & AGA Standard and Known-Air-Infiltration Rate Methods

Air for Combustion, Ventilation, and Dilution for Outdoors

Combination of Indoor and Outdoor Air

CONDENSATE TRAP

Condensate Trap - Horizontal Orientation

Condensate Drain Connection

CAUTION Frozen and Burst Water Pipe Hazard

Cautions about freezing risk to drain lines and equipment.

CAUTION Property Damage Hazard

Cautions about property damage from burst pipes due to condensate.

Return Air Connections

FIRE HAZARD WARNING

Warns against connecting return air ducts to the back of the furnace.

WARNING FIRE, EXPLOSION, AND CARBON MONOXIDE POISONING HAZARD

CAUTION MINOR PROPERTY HAZARD

Filter Arrangement

WARNING Fire, Carbon Monoxide and Poisoning Hazard

Warns about operating without a filter or with access doors removed.

Air Ducts

GAS PIPING

WARNING Fire or Explosion Hazard

WARNING Fire or Explosion Hazard

Warns about flexible gas appliance connectors and black iron pipe.

CAUTION Furnace Damage Hazard

Cautions about using a backup wrench for gas pipe connections.

ELECTRICAL CONNECTIONS

WARNING Electrical Shock Hazard

Warns about blower door switch and field wiring connections.

WARNING Electrical Shock and Fire Hazard

Warns about cabinet grounding requirements.

115-V Wiring

WARNING Fire Hazard

J-Box Installation

WARNING Fire or Electrical Shock Hazard

Warns about mounting disconnect switches on furnace casing.

Power Cord Installation in Furnace J-Box

BX Cable Installation in Furnace J-Box

24-V Wiring

Thermostats and Control Settings for (F/G)9MVT Variable Speed Furnaces

Thermostats and Control Settings for (F/G)9MXT Two-Stage Furnaces

Thermostats and Control Settings for (F/G)9MXE Single-Stage Furnaces

Alternate Power Supplies

VENTING

Venting Systems

WARNING Carbon Monoxide Poisoning Hazard

Locating the Vent Termination

Termination Requirements for the Provinces of Alberta and Saskatchewan

Size the Vent and Combustion Air Pipes

NOTICE Additional Information for Polypropylene Venting Systems

Venting System Length Calculations

Install the Vent and Combustion Air Pipes

Installing the Vent Pipe Adapter and Combustion Air Pipe Adapter

Optional Installation of the Vent Pipe

Installing the Vent Termination

WARNING Carbon Monoxide Poisoning Hazard

Warns against using cement for polypropylene venting systems.

Inducer Outlet Restrictor (PSC models only)

Related product manuals