EasyManua.ls Logo

ICP G9MAE0801714A User Manual

ICP G9MAE0801714A
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Printed in U.S.A. 440 04 4700 00 Aug. 2012
SERVICE AND TECHNICAL
SUPPORT MANUAL
Modulating, Variable Speed Blower Motor
35” Tall, High Efficiency Condensing Gas Furnace
(
F/G
)
9MAE
Save this manual for future reference.
Safety Labeling and Signal Words
DANGER, WARNING, CAUTION, and NOTE
The signal words DANGER, WARNING,
CAUTION, and NOTE are used to identify levels of
hazard seriousness. The signal word DANGER is
only used on product labels to signify an immediate
hazard. The signal words WARNING, CAUTION,
and NOTE will be used on product labels and
throughout this manual and other manual that may
apply to the product.
DANGER Immediate hazards which will result in
severe personal injury or death.
WARNING Hazards or unsafe practices which
could result in severe personal injury or death.
CAUTION Hazards or unsafe practices which
may result in minor personal injury or product or
property damage.
NOTE Used to highlight suggestions which will
result in enhanced installation, reliability, or
operation.
!
WARNING
Signal Words in Manuals
The signal word CAUTION is used throughout
this manual in the following manner:
!
CAUTION
Signal Words on Product Labeling
Signal words are used in combination with
colors and/or pictures or product labels.
The signal word WARNING is used throughout
this manual in the following manner:
Safetyalert symbol
When you see this symbol on the unit and in
instructions or manuals, be alert to the
potential for personal injury.
TABLE OF CONTENTS
STARTUP, ADJUSTMENT, AND SAFETY CHECK 4...........
SELECT SETUP SWITCH POSITIONS 4.....................
PRIME CONDENSATE TRAP WITH WATER 4.................
PURGE GAS LINES 5......................................
ADJUSTMENTS 5.........................................
ADJUST TEMPERATURE RISE 8............................
ADJUST BLOWER OFF DELAY (HEAT MODE) 9..............
ADJUST COOLING AIRFLOW 9.............................
ADJUST CONTINUOUS FAN AIRFLOW 9....................
ADJUST THERMOSTAT HEAT ANTICIPATOR 11...............
CHECK SAFETY CONTROLS 12.............................
CHECKLIST 12.............................................
COOLING AND HEATING AIR DELIVERY - CFM 17.............
SERVICE AND MAINTENANCE PROCEDURES 21.............
ELECTRICAL CONTROLS AND WIRING 21...................
CLEANING AND/OR REPLACING AIR FILTER 23..............
CLEANING BURNERS AND FLAME SENSOR 25...............
SERVICING HOT SURFACE IGNITER 26......................
FLUSHING COLLECTOR BOX AND DRAINAGE SYSTEM 27....
CLEANING CONDENSATE DRAIN AND TRAP 27..............
WINTERIZATION 28........................................
SERVICE LABEL 29.........................................
TROUBLESHOOTING CHART FLOW CHART 31.............
TROUBLESHOOTING GUIDE FLOW CHART 32..............
SEQUENCE OF OPERATION 34.............................
PARTS REPLACEMENT INFORMATION GUIDE 38.............
PRODUCT NOMENCLATURE 39.............................
MODELS
(F/G)9MAE0601714A
(F/G)9MAE0602120A
(F/G)9MAE0801714A
(F/G)9MAE0802120A
(F/G)9MAE1002122A
(F/G)9MAE1202422A
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program.
For verification of certification for individual
products, go to www.ahridirectory.org .
Question and Answer IconNeed help?

Do you have a question about the ICP G9MAE0801714A and is the answer not in the manual?

ICP G9MAE0801714A Specifications

General IconGeneral
BrandICP
ModelG9MAE0801714A
CategoryFurnace
LanguageEnglish

Summary

Safety Labeling and Signal Words

Signal Words in Manuals

Explains signal word usage in manuals for hazard identification.

Signal Words on Product Labeling

Explains signal word usage on product labels for hazard identification.

Safety-alert symbol

Explains the safety-alert symbol for personal injury awareness.

SAFETY CONSIDERATIONS

PERSONAL INJURY, AND/OR PROPERTY DAMAGE HAZARD

Warning about hazards causing severe personal injury or death.

ELECTRICAL SHOCK HAZARD

Warning about electrical shock risks leading to injury or death.

CARBON MONOXIDE POISONING AND FIRE HAZARD

Warning regarding CO poisoning and fire risks.

CUT HAZARD

Caution about sharp edges causing cuts and injury.

START-UP, ADJUSTMENT, AND SAFETY CHECK

Select Setup Switch Positions

Guides on configuring furnace setup switches for application requirements.

Prime Condensate Trap with Water

Instructions for priming the condensate trap to ensure proper draining.

Purge Gas Lines

Procedure for purging gas lines and checking for leaks before operation.

Adjustments

Check Inlet Gas Pressure

Procedure to verify inlet gas pressure for proper furnace input.

Adjust Temperature Rise

Adjust Cooling Airflow – High-Speed and Low-Speed Cooling

Adjust Continuous Fan Airflow/Low Speed Cooling Airflow

Adjust Thermostat Heat Anticipator

Check Safety Controls

SERVICE AND MAINTENANCE PROCEDURES

Troubleshooting

General guidance on diagnosing and resolving furnace issues.

Retrieving Stored Fault Codes

Component Self-Test

Service Label and Status Codes

Troubleshooting Guide – Flow Chart

Care and Maintenance

Cleaning Burners and Flame Sensor

Servicing Hot Surface Igniter

Cleaning Heat Exchangers

Winterization

SEQUENCE OF OPERATION

Cooling Mode

Related product manuals