EasyManua.ls Logo

ICP G9MVE0601714A2 User Manual

ICP G9MVE0601714A2
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Printed in U.S.A. 440 04 4801 00 7/3/2014
SERVICE AND TECHNICAL
SUPPORT MANUAL
TwoStage, Variable Speed ECM Blower Motor
35” Tall, High Efficiency Condensing Gas Furnace
(F/G)9MVE ’A2’ Series
Save this manual for future reference.
Safety Labeling and Signal Words
DANGER, WARNING, CAUTION, and NOTE
The signal words DANGER, WARNING,
CAUTION, and NOTE are used to identify levels of
hazard seriousness. The signal word DANGER is
only used on product labels to signify an immediate
hazard. The signal words WARNING, CAUTION,
and NOTE will be used on product labels and
throughout this manual and other manual that may
apply to the product.
DANGER Immediate hazards which will result in
severe personal injury or death.
WARNING Hazards or unsafe practices which
could result in severe personal injury or death.
CAUTION Hazards or unsafe practices which
may result in minor personal injury or product or
property damage.
NOTE Used to highlight suggestions which will
result in enhanced installation, reliability, or
operation.
!
WARNING
Signal Words in Manuals
The signal word CAUTION is used throughout
this manual in the following manner:
!
CAUTION
Signal Words on Product Labeling
Signal words are used in combination with
colors and/or pictures or product labels.
The signal word WARNING is used throughout
this manual in the following manner:
Safetyalert symbol
When you see this symbol on the unit and in
instructions or manuals, be alert to the
potential for personal injury.
TABLE OF CONTENTS
STARTUP, ADJUSTMENT, AND SAFETY CHECK 4...........
SETUP SWITCHES 4......................................
PRIME CONDENSATE TRAP WITH WATER 4.................
PURGE GAS LINES 5......................................
ADJUSTMENTS 5.........................................
ADJUST TEMPERATURE RISE 11............................
ADJUST BLOWER OFF DELAY (HEAT MODE) 12..............
ADJUST COOLING AIRFLOW 12.............................
ADJUST CONTINUOUS FAN AIRFLOW 12....................
ADJUST THERMOSTAT HEAT ANTICIPATOR 14...............
CHECK SAFETY CONTROLS 14.............................
CHECKLIST 14.............................................
COOLING AND HEATING AIR DELIVERY - CFM 15.............
SERVICE AND MAINTENANCE PROCEDURES 17.............
ELECTRICAL CONTROLS AND WIRING 17...................
CLEANING AND/OR REPLACING AIR FILTER 19..............
BLOWER MOTOR AND WHEEL MAINTENANCE 20............
CLEANING BURNERS AND FLAME SENSOR 21...............
SERVICING HOT SURFACE IGNITER 22......................
FLUSHING COLLECTOR BOX AND DRAINAGE SYSTEM 23....
CLEANING CONDENSATE DRAIN AND TRAP 23..............
CLEANING HEAT EXCHANGERS 23..........................
SERVICE LABEL 26.........................................
WIRING DIAGRAM 27.......................................
TROUBLESHOOTING GUIDE FLOW CHART 28..............
SEQUENCE OF OPERATION 30.............................
PARTS REPLACEMENT INFORMATION GUIDE 35.............
PRODUCT NOMENCLATURE 36.............................
MODELS
(F/G)9MVE0401410A2
(F/G)9MVE0401712A2
(F/G)9MVE0601412A2
(F/G)9MVE0601714A2
(F/G)9MVE0801716A2
(F/G)9MVE0802120A2
(F/G)9MVE1002120A2
(F/G)9MVE1202422A2
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program.
For verification of certification for individual
products, go to www.ahridirectory.org .
Question and Answer IconNeed help?

Do you have a question about the ICP G9MVE0601714A2 and is the answer not in the manual?

ICP G9MVE0601714A2 Specifications

General IconGeneral
BrandICP
ModelG9MVE0601714A2
CategoryFurnace
LanguageEnglish

Summary

Safety Considerations

General Safety Precautions

Discusses installation, adjustment, alteration, service, and maintenance safety.

Hazard Warnings and Cautions

Covers personal injury, electrical shock, carbon monoxide, fire, and cut hazards.

Start-Up, Adjustment, and Safety Check

Setup Switch Configuration

Details setup switches (SW1, SW2, CF, AC) for application settings and airflow.

Adjustments

Manifold Pressure Adjustment

Guidance on adjusting manifold pressure for proper input rate and flame characteristics.

Altitude and Inlet Gas Pressure Adjustments

Altitude Derate and Orifice Selection

Explains altitude derating and how to select correct orifices based on gas properties.

Checking Inlet Gas Pressure

Procedure to check inlet gas pressure for proper furnace operation.

Manifold Pressure Adjustment

Low-Heat Adjustment

Steps to adjust manifold pressure for the low-fire input rate.

High-Heat Adjustment

Steps to adjust manifold pressure for the high-fire input rate.

Adjust Temperature Rise

Temperature Rise Measurement

Procedure to measure air temperature rise for furnace operation verification.

Adjusting Temperature Rise

Steps to troubleshoot and adjust temperature rise if it is outside specified limits.

System Checks and Adjustments

Adjust Thermostat Heat Anticipator

Procedure to set the heat anticipator based on amp draw.

Check Safety Controls

Verifies operation of main limit and pressure switches for safety.

Service Label and Diagnostic Codes

Understanding Status Codes

Explains LED codes and how to interpret single/two-digit status codes.

Wiring Diagrams and Troubleshooting Guide

Troubleshooting Flow Chart

A guide to diagnose and resolve furnace operational issues step-by-step.

Related product manuals