About MPS
About MPS
Conventional (On/Off Operation)
• During a Conventional Air Conditioning
Cycle, the Compressor must turn on and
off to reach desired Temperature setting.
• A large portion of power is used during
Restart.
This causes unnecessary power
consumption.
27
25
23
21
19
0
0:05 0:10 0:15 0:20
Operation time (min)
Indoor Temp (°C)
ON OFF ON OFF
MPS
• MPS(Multi Power System) is a power
saving system With Two rotary
compressors of different capacity (60%
& 40%) Operating an A/C at high power
until it reaches desired temperature.
• And when it reaches the temperature,
only the 40% Capacity rotary
compressor operates.
27
25
23
21
19
0
0:05
100% operation 40% operation
0:10 0:15 0:20
Operation time (min)
Indoor Temp (°C)
Service Manual 7
MPS (Multi Power System)