Printed in U.S.A. 440 04 4413 00 3/25/2014
SERVICE AND TECHNICAL
SUPPORT MANUAL
Single Stage, PSC Blower Motor
35” Tall, High Efficiency Condensing Gas Furnace
N9MSB (C Series)
Save this manual for future reference.
Safety Labeling and Signal Words
DANGER, WARNING, CAUTION, and NOTE
The signal words DANGER, WARNING,
CAUTION, and NOTE are used to identify levels of
hazard seriousness. The signal word DANGER is
only used on product labels to signify an immediate
hazard. The signal words WARNING, CAUTION,
and NOTE will be used on product labels and
throughout this manual and other manual that may
apply to the product.
DANGER Immediate hazards which will result in
severe personal injury or death.
WARNING Hazards or unsafe practices which
could result in severe personal injury or death.
CAUTION Hazards or unsafe practices which
may result in minor personal injury or product or
property damage.
NOTE Used to highlight suggestions which will
result in enhanced installation, reliability, or
operation.
!
WARNING
Signal Words in Manuals
The signal word CAUTION is used throughout
this manual in the following manner:
!
CAUTION
Signal Words on Product Labeling
Signal words are used in combination with
colors and/or pictures or product labels.
The signal word WARNING is used throughout
this manual in the following manner:
Safetyalert symbol
When you see this symbol on the unit and in
instructions or manuals, be alert to the
potential for personal injury.
TABLE OF CONTENTS
STARTUP CHECK SHEET FOR PSC MOTOR 3..............
STARTUP, ADJUSTMENT, AND SAFETY CHECK 4...........
PRIME CONDENSATE TRAP WITH WATER 4.................
PURGE GAS LINES 4......................................
ADJUST TEMPERATURE RISE 10............................
ADJUST BLOWER OFF DELAY (HEAT MODE) 11..............
ADJUST COOLING AIRFLOW 11.............................
ADJUST THERMOSTAT HEAT ANTICIPATOR 11...............
CHECK SAFETY CONTROLS 11.............................
COOLING AIR DELIVERY - CFM 12...........................
CHECKLIST 12.............................................
SERVICE AND MAINTENANCE PROCEDURES 13.............
RETRIEVING STORED FAULT CODES 14.....................
COMPONENT SELFTEST 14...............................
CARE AND MAINTENANCE 15...............................
CLEANING AND/OR REPLACING AIR FILTER 15..............
BLOWER MOTOR AND WHEEL MAINTENANCE 15............
CLEANING BURNERS AND FLAME SENSOR 17...............
SERVICING HOT SURFACE IGNITER 18......................
FLUSHING COLLECTOR BOX AND DRAINAGE SYSTEM 18....
CLEANING CONDENSATE DRAIN AND TRAP 19..............
CLEANING HEAT EXCHANGERS 19..........................
WINTERIZATION 20........................................
SERVICE LABEL 21.........................................
WIRING DIAGRAM 22.......................................
TROUBLESHOOTING GUIDE FLOW CHART 23..............
SEQUENCE OF OPERATION 25.............................
PARTS REPLACEMENT INFORMATION GUIDE 26.............
PRODUCT NOMENCLATURE 27.............................
MODELS
N9MSB0401410C
N9MSB0401712C
N9MSB0601412C
N9MSB0601716C
N9MSB0801716C
N9MSB0802120C
N9MSB1002116C
N9MSB1002120C
N9MSB1202420C
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program.
For verification of certification for individual
products, go to www.ahridirectory.org .

Questions and Answers:

ICP N9MSB0601412C Specifications

General IconGeneral
BrandICP
ModelN9MSB0601412C
CategoryFurnace
LanguageEnglish

Summary

Safety Labeling and Signal Words

Signal Words in Manuals

Defines signal words used in manuals for hazard identification.

Signal Words on Product Labeling

Explains signal words used on product labels in combination with colors/pictures.

SAFETY CONSIDERATIONS

START-UP, ADJUSTMENT, AND SAFETY CHECK

Prime Condensate Trap with Water

Procedure for priming the condensate trap to ensure proper drainage.

Purge Gas Lines

Instructions for purging gas lines to remove air and check for leaks.

Check Inlet Gas Pressure

Adjust Manifold Pressure

Steps to adjust the manifold pressure for proper gas input rate.

Adjust Temperature Rise

Adjust Blower Off Delay (Heat Mode)

Adjust Thermostat Heat Anticipator

Steps to set the thermostat's heat anticipator based on component amp draw.

Check Safety Controls

SERVICE AND MAINTENANCE PROCEDURES

Electrical Controls and Wiring

Details on furnace electrical controls, wiring, and troubleshooting aids.

Pressure Switches

Explanation of pressure switch operation and specifications.

Troubleshooting

Overview of troubleshooting methods, including status codes and flow charts.

Retrieving Stored Fault Codes

Component Self-Test

Instructions for initiating and performing a component self-test sequence.

Care and Maintenance

Cleaning Burners and Flame Sensor

Cleaning Heat Exchangers

SERVICE LABEL

Troubleshooting Guide

SEQUENCE OF OPERATION

PARTS REPLACEMENT INFORMATION GUIDE

PRODUCT NOMENCLATURE