EasyManua.ls Logo

ICP N9MSB1002120C User Manual

ICP N9MSB1002120C
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Printed in U.S.A. 440 04 4413 00 3/25/2014
SERVICE AND TECHNICAL
SUPPORT MANUAL
Single Stage, PSC Blower Motor
35” Tall, High Efficiency Condensing Gas Furnace
N9MSB (C Series)
Save this manual for future reference.
Safety Labeling and Signal Words
DANGER, WARNING, CAUTION, and NOTE
The signal words DANGER, WARNING,
CAUTION, and NOTE are used to identify levels of
hazard seriousness. The signal word DANGER is
only used on product labels to signify an immediate
hazard. The signal words WARNING, CAUTION,
and NOTE will be used on product labels and
throughout this manual and other manual that may
apply to the product.
DANGER Immediate hazards which will result in
severe personal injury or death.
WARNING Hazards or unsafe practices which
could result in severe personal injury or death.
CAUTION Hazards or unsafe practices which
may result in minor personal injury or product or
property damage.
NOTE Used to highlight suggestions which will
result in enhanced installation, reliability, or
operation.
!
WARNING
Signal Words in Manuals
The signal word CAUTION is used throughout
this manual in the following manner:
!
CAUTION
Signal Words on Product Labeling
Signal words are used in combination with
colors and/or pictures or product labels.
The signal word WARNING is used throughout
this manual in the following manner:
Safetyalert symbol
When you see this symbol on the unit and in
instructions or manuals, be alert to the
potential for personal injury.
TABLE OF CONTENTS
STARTUP CHECK SHEET FOR PSC MOTOR 3..............
STARTUP, ADJUSTMENT, AND SAFETY CHECK 4...........
PRIME CONDENSATE TRAP WITH WATER 4.................
PURGE GAS LINES 4......................................
ADJUST TEMPERATURE RISE 10............................
ADJUST BLOWER OFF DELAY (HEAT MODE) 11..............
ADJUST COOLING AIRFLOW 11.............................
ADJUST THERMOSTAT HEAT ANTICIPATOR 11...............
CHECK SAFETY CONTROLS 11.............................
COOLING AIR DELIVERY - CFM 12...........................
CHECKLIST 12.............................................
SERVICE AND MAINTENANCE PROCEDURES 13.............
RETRIEVING STORED FAULT CODES 14.....................
COMPONENT SELFTEST 14...............................
CARE AND MAINTENANCE 15...............................
CLEANING AND/OR REPLACING AIR FILTER 15..............
BLOWER MOTOR AND WHEEL MAINTENANCE 15............
CLEANING BURNERS AND FLAME SENSOR 17...............
SERVICING HOT SURFACE IGNITER 18......................
FLUSHING COLLECTOR BOX AND DRAINAGE SYSTEM 18....
CLEANING CONDENSATE DRAIN AND TRAP 19..............
CLEANING HEAT EXCHANGERS 19..........................
WINTERIZATION 20........................................
SERVICE LABEL 21.........................................
WIRING DIAGRAM 22.......................................
TROUBLESHOOTING GUIDE FLOW CHART 23..............
SEQUENCE OF OPERATION 25.............................
PARTS REPLACEMENT INFORMATION GUIDE 26.............
PRODUCT NOMENCLATURE 27.............................
MODELS
N9MSB0401410C
N9MSB0401712C
N9MSB0601412C
N9MSB0601716C
N9MSB0801716C
N9MSB0802120C
N9MSB1002116C
N9MSB1002120C
N9MSB1202420C
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program.
For verification of certification for individual
products, go to www.ahridirectory.org .

Questions and Answers:

ICP N9MSB1002120C Specifications

General IconGeneral
BrandICP
ModelN9MSB1002120C
CategoryFurnace
LanguageEnglish

Summary

Safety Labeling and Signal Words

Signal Word Definitions

Explains the meaning of DANGER, WARNING, CAUTION, and NOTE signal words used in manuals and on products.

Safety Considerations

General Safety Precautions

Covers general safety rules, codes, and protective gear recommendations for installation and service.

Personal Injury and Property Damage Warning

Warns about potential personal injury or property damage from improper installation or unqualified service.

Gas Input Rate and Orifice Adjustment

Orifice Hole and Furnace Damage Caution

Warns against improper orifice drilling, which can cause excessive noise and heat exchanger failures.

Altitude Derating and Orifice Selection

Details how altitude affects gas input and provides tables for selecting correct orifices based on altitude and gas properties.

Gas Pressure Checks and Adjustments

Check Inlet Gas Pressure

Step-by-step guide to checking inlet gas pressure while the furnace is operating in maximum heat.

Adjust Manifold Pressure

Instructions on how to adjust manifold pressure to obtain the proper gas input rate for efficient operation.

Service and Maintenance Procedures

Troubleshooting and Diagnostics

Retrieving Stored Fault Codes

Explains how to access and interpret stored fault codes from the furnace control via the status LED.

Component Self-Test

Describes the procedure for running a component self-test to diagnose system issues by cycling through parts.

Care and Maintenance

Diagnostic Codes and Tests

LED Status Codes

Explains the meaning of various LED status codes displayed by the control board for furnace diagnostics.

Component Test

Details the procedure for running a component test sequence to verify the function of the inducer, igniter, and blower motors.

Troubleshooting Guide

Flow Chart Navigation

Visual guide for diagnosing furnace issues step-by-step using a flowchart starting from initial checks.

Status Code Interpretation

Explains how to interpret status codes displayed by the LED and the control board for troubleshooting.

Related product manuals