Printed in U.S.A. 440 04 4413 00 3/25/2014
SERVICE AND TECHNICAL
SUPPORT MANUAL
Single Stage, PSC Blower Motor
35” Tall, High Efficiency Condensing Gas Furnace
N9MSB (C Series)
Save this manual for future reference.
Safety Labeling and Signal Words
DANGER, WARNING, CAUTION, and NOTE
The signal words DANGER, WARNING,
CAUTION, and NOTE are used to identify levels of
hazard seriousness. The signal word DANGER is
only used on product labels to signify an immediate
hazard. The signal words WARNING, CAUTION,
and NOTE will be used on product labels and
throughout this manual and other manual that may
apply to the product.
DANGER Immediate hazards which will result in
severe personal injury or death.
WARNING Hazards or unsafe practices which
could result in severe personal injury or death.
CAUTION Hazards or unsafe practices which
may result in minor personal injury or product or
property damage.
NOTE Used to highlight suggestions which will
result in enhanced installation, reliability, or
operation.
!
WARNING
Signal Words in Manuals
The signal word CAUTION is used throughout
this manual in the following manner:
!
CAUTION
Signal Words on Product Labeling
Signal words are used in combination with
colors and/or pictures or product labels.
The signal word WARNING is used throughout
this manual in the following manner:
Safetyalert symbol
When you see this symbol on the unit and in
instructions or manuals, be alert to the
potential for personal injury.
TABLE OF CONTENTS
STARTUP CHECK SHEET FOR PSC MOTOR 3..............
STARTUP, ADJUSTMENT, AND SAFETY CHECK 4...........
PRIME CONDENSATE TRAP WITH WATER 4.................
PURGE GAS LINES 4......................................
ADJUST TEMPERATURE RISE 10............................
ADJUST BLOWER OFF DELAY (HEAT MODE) 11..............
ADJUST COOLING AIRFLOW 11.............................
ADJUST THERMOSTAT HEAT ANTICIPATOR 11...............
CHECK SAFETY CONTROLS 11.............................
COOLING AIR DELIVERY - CFM 12...........................
CHECKLIST 12.............................................
SERVICE AND MAINTENANCE PROCEDURES 13.............
RETRIEVING STORED FAULT CODES 14.....................
COMPONENT SELFTEST 14...............................
CARE AND MAINTENANCE 15...............................
CLEANING AND/OR REPLACING AIR FILTER 15..............
BLOWER MOTOR AND WHEEL MAINTENANCE 15............
CLEANING BURNERS AND FLAME SENSOR 17...............
SERVICING HOT SURFACE IGNITER 18......................
FLUSHING COLLECTOR BOX AND DRAINAGE SYSTEM 18....
CLEANING CONDENSATE DRAIN AND TRAP 19..............
CLEANING HEAT EXCHANGERS 19..........................
WINTERIZATION 20........................................
SERVICE LABEL 21.........................................
WIRING DIAGRAM 22.......................................
TROUBLESHOOTING GUIDE FLOW CHART 23..............
SEQUENCE OF OPERATION 25.............................
PARTS REPLACEMENT INFORMATION GUIDE 26.............
PRODUCT NOMENCLATURE 27.............................
MODELS
N9MSB0401410C
N9MSB0401712C
N9MSB0601412C
N9MSB0601716C
N9MSB0801716C
N9MSB0802120C
N9MSB1002116C
N9MSB1002120C
N9MSB1202420C
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program.
For verification of certification for individual
products, go to www.ahridirectory.org .

Questions and Answers:

ICP N9MSB0801716C Specifications

General IconGeneral
BrandICP
ModelN9MSB0801716C
CategoryFurnace
LanguageEnglish

Summary

Safety Labeling and Signal Words

Signal Words in Manuals

Explains the use of signal words like WARNING and CAUTION within the manual text.

Signal Words on Product Labeling

Details how signal words are used on product labels in combination with colors and pictures.

SAFETY CONSIDERATIONS

Personal Injury and Property Damage Hazard

Warns about hazards that could result in severe personal injury, death, or property damage.

Electrical Shock Hazard

Alerts users to the risk of electric shock, personal injury, or death from electrical hazards.

Carbon Monoxide Poisoning and Fire Hazard

Highlights risks of carbon monoxide poisoning and fire, with specific usage limitations.

Cut Hazard

Warns about sharp edges on sheet metal parts that can cause cuts and injuries.

START-UP AND ADJUSTMENT PROCEDURES

Manifold Pressure and Gas Input

Orifice Hole Inspection and Size Verification

Guidance on inspecting and verifying burner orifices for proper gas input rate.

Adjusting Manifold Pressure for Gas Input

Steps to adjust manifold pressure to achieve the correct gas input rate based on altitude and gas heat value.

Inlet Gas Pressure and Manifold Adjustment

Checking Inlet Gas Pressure

Procedure to measure and verify the inlet gas pressure to the furnace during operation.

Adjusting Manifold Pressure

Detailed steps for adjusting the gas valve regulator to set the correct manifold pressure.

Temperature Rise and Blower Speed Adjustment

Adjusting Temperature Rise

Procedures to measure and ensure proper air temperature rise across the heat exchanger.

Adjusting Blower Speed Taps

Instructions on how to change blower motor speed selections for optimal airflow and temperature rise.

Furnace Operation Checks

Check Safety Controls

Procedures to test the main limit switch and pressure switches for proper operation.

Fault Code Retrieval and Component Testing

Service Label and Troubleshooting Codes

Troubleshooting Flow Chart

Troubleshooting Specific Faults

Furnace Sequence of Operation