SERVICE AND TECHNICAL
SUPPORT MANUAL
Single Stage, PSC Blower Motor
35” Tall, High Efficiency Condensing Gas Furnace
N9MSB (C Series)
Save this manual for future reference.
Safety Labeling and Signal Words
DANGER, WARNING, CAUTION, and NOTE
The signal words DANGER, WARNING,
CAUTION, and NOTE are used to identify levels of
hazard seriousness. The signal word DANGER is
only used on product labels to signify an immediate
hazard. The signal words WARNING, CAUTION,
and NOTE will be used on product labels and
throughout this manual and other manual that may
apply to the product.
DANGER Immediate hazards which will result in
severe personal injury or death.
WARNING Hazards or unsafe practices which
could result in severe personal injury or death.
CAUTION Hazards or unsafe practices which
may result in minor personal injury or product or
property damage.
NOTE Used to highlight suggestions which will
result in enhanced installation, reliability, or
operation.
!
WARNING
Signal Words in Manuals
The signal word CAUTION is used throughout
this manual in the following manner:
!
CAUTION
Signal Words on Product Labeling
Signal words are used in combination with
colors and/or pictures or product labels.
The signal word WARNING is used throughout
this manual in the following manner:
Safetyalert symbol
When you see this symbol on the unit and in
instructions or manuals, be alert to the
potential for personal injury.
TABLE OF CONTENTS
STARTUP CHECK SHEET FOR PSC MOTOR 3..............
STARTUP, ADJUSTMENT, AND SAFETY CHECK 4...........
PRIME CONDENSATE TRAP WITH WATER 4.................
PURGE GAS LINES 4......................................
ADJUST TEMPERATURE RISE 10............................
ADJUST BLOWER OFF DELAY (HEAT MODE) 11..............
ADJUST COOLING AIRFLOW 11.............................
ADJUST THERMOSTAT HEAT ANTICIPATOR 11...............
CHECK SAFETY CONTROLS 11.............................
COOLING AIR DELIVERY - CFM 12...........................
CHECKLIST 12.............................................
SERVICE AND MAINTENANCE PROCEDURES 13.............
RETRIEVING STORED FAULT CODES 14.....................
COMPONENT SELFTEST 14...............................
CARE AND MAINTENANCE 15...............................
CLEANING AND/OR REPLACING AIR FILTER 15..............
BLOWER MOTOR AND WHEEL MAINTENANCE 15............
CLEANING BURNERS AND FLAME SENSOR 17...............
SERVICING HOT SURFACE IGNITER 18......................
FLUSHING COLLECTOR BOX AND DRAINAGE SYSTEM 18....
CLEANING CONDENSATE DRAIN AND TRAP 19..............
CLEANING HEAT EXCHANGERS 19..........................
WINTERIZATION 20........................................
SERVICE LABEL 21.........................................
WIRING DIAGRAM 22.......................................
TROUBLESHOOTING GUIDE FLOW CHART 23..............
SEQUENCE OF OPERATION 25.............................
PARTS REPLACEMENT INFORMATION GUIDE 26.............
PRODUCT NOMENCLATURE 27.............................
MODELS
N9MSB0401410C
N9MSB0401712C
N9MSB0601412C
N9MSB0601716C
N9MSB0801716C
N9MSB0802120C
N9MSB1002116C
N9MSB1002120C
N9MSB1202420C
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program.
For verification of certification for individual
products, go to www.ahridirectory.org .

Questions and Answers:

ICP N9MSB0401410C Specifications

General IconGeneral
BrandICP
ModelN9MSB0401410C
CategoryFurnace
LanguageEnglish

Summary

Safety Labeling and Signal Words

Safety Considerations

General Safety Precautions

Highlights general safety codes and the use of safety-alert symbols for personal injury.

Hazard Signal Words

Defines DANGER, WARNING, and CAUTION for hazard seriousness and potential injury or damage.

Specific Hazard Warnings

Details specific hazards like personal injury, electrical shock, carbon monoxide, and cut hazards.

Start-Up, Adjustment, and Safety Check

Unit Operation Hazards

Warns about manual reset limit switches and the need to correct issues before resetting.

Prime Condensate Trap

Provides instructions for priming the condensate trap with water to prevent vent gas entry.

Purge Gas Lines

Details procedures for purging gas lines and checking for leaks, emphasizing safety precautions.

Orifice and Gas Input Adjustments

Orifice Hole Inspection

Instructions on checking and verifying burner orifice size to ensure proper flame characteristics.

Inlet Gas Pressure and Manifold Adjustment

Check Inlet Gas Pressure

Procedure to check inlet gas pressure during maximum heat operation.

Adjust Manifold Pressure

Step-by-step guide to adjusting manifold pressure for proper gas input rate.

Verify Gas Input Rate

Procedure for verifying natural gas input rate by clocking the meter.

Orifice Size and Manifold Pressure Tables

Temperature Rise Adjustment

Blower Operation Adjustments

Check Safety Controls

Service and Maintenance Procedures

Troubleshooting Guidance

Guidance on using the Status Code LED and Flow Chart for diagnosing furnace problems.

Furnace Wiring Diagram and Fault Codes

Retrieving Stored Fault Codes

Procedure for retrieving stored fault codes using the status LED.

Component Self-Test Procedure

Procedure to initiate a self-test sequence for furnace components.

Care and Maintenance Tasks

Burner and Flame Sensor Service

Collector Box and Drainage System Flushing

Condensate Drain and Trap Service

Heat Exchanger Cleaning

Furnace Winterization

Service Label and Diagnostics

LED Status Codes Interpretation

Explanation of LED status codes for diagnosing furnace operational issues.

Component Test Sequence

Details the component test sequence for furnace diagnostics.

Troubleshooting Guide Flow Chart

Sequence of Operation

Parts Replacement Information Guide

Related product manuals