Single Stage, PSC Blower Motor
35” Tall, High Efficiency Condensing Gas Furnace
N9MSB (C Series)
Save this manual for future reference.
Safety Labeling and Signal Words
DANGER, WARNING, CAUTION, and NOTE
The signal words DANGER, WARNING,
CAUTION, and NOTE are used to identify levels of
hazard seriousness. The signal word DANGER is
only used on product labels to signify an immediate
hazard. The signal words WARNING, CAUTION,
and NOTE will be used on product labels and
throughout this manual and other manual that may
apply to the product.
DANGER Immediate hazards which will result in
severe personal injury or death.
WARNING Hazards or unsafe practices which
could result in severe personal injury or death.
CAUTION Hazards or unsafe practices which
may result in minor personal injury or product or
property damage.
NOTE Used to highlight suggestions which will
result in enhanced installation, reliability, or
operation.
!
WARNING
Signal Words in Manuals
The signal word CAUTION is used throughout
this manual in the following manner:
!
CAUTION
Signal Words on Product Labeling
Signal words are used in combination with
colors and/or pictures or product labels.
The signal word WARNING is used throughout
this manual in the following manner:
Safetyalert symbol
When you see this symbol on the unit and in
instructions or manuals, be alert to the
potential for personal injury.
TABLE OF CONTENTS
STARTUP CHECK SHEET FOR PSC MOTOR 3..............
STARTUP, ADJUSTMENT, AND SAFETY CHECK 4...........
PRIME CONDENSATE TRAP WITH WATER 4.................
PURGE GAS LINES 4......................................
ADJUST TEMPERATURE RISE 10............................
ADJUST BLOWER OFF DELAY (HEAT MODE) 11..............
ADJUST COOLING AIRFLOW 11.............................
ADJUST THERMOSTAT HEAT ANTICIPATOR 11...............
CHECK SAFETY CONTROLS 11.............................
COOLING AIR DELIVERY - CFM 12...........................
CHECKLIST 12.............................................
SERVICE AND MAINTENANCE PROCEDURES 13.............
RETRIEVING STORED FAULT CODES 14.....................
COMPONENT SELFTEST 14...............................
CARE AND MAINTENANCE 15...............................
CLEANING AND/OR REPLACING AIR FILTER 15..............
BLOWER MOTOR AND WHEEL MAINTENANCE 15............
CLEANING BURNERS AND FLAME SENSOR 17...............
SERVICING HOT SURFACE IGNITER 18......................
FLUSHING COLLECTOR BOX AND DRAINAGE SYSTEM 18....
CLEANING CONDENSATE DRAIN AND TRAP 19..............
CLEANING HEAT EXCHANGERS 19..........................
WINTERIZATION 20........................................
SERVICE LABEL 21.........................................
WIRING DIAGRAM 22.......................................
TROUBLESHOOTING GUIDE FLOW CHART 23..............
SEQUENCE OF OPERATION 25.............................
PARTS REPLACEMENT INFORMATION GUIDE 26.............
PRODUCT NOMENCLATURE 27.............................
MODELS
N9MSB0401410C
N9MSB0401712C
N9MSB0601412C
N9MSB0601716C
N9MSB0801716C
N9MSB0802120C
N9MSB1002116C
N9MSB1002120C
N9MSB1202420C
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program.
For verification of certification for individual
products, go to www.ahridirectory.org .

Questions and Answers:

ICP N9MSB0601716C Specifications

General IconGeneral
BrandICP
ModelN9MSB0601716C
CategoryFurnace
LanguageEnglish

Summary

Safety Labeling and Signal Words

Safety Considerations and Hazards

General Safety Precautions

Outlines essential safety practices for installation, service, and maintenance of the furnace.

Personal Injury and Property Damage Warnings

Highlights hazards that could lead to severe injury, death, or property damage.

Electrical Shock Hazard Warning

Warns about the dangers of electrical shock during service and maintenance.

Carbon Monoxide Poisoning and Fire Hazard

Addresses risks of carbon monoxide and fire, and furnace limitations.

Start-Up, Adjustment, and Safety Checks

Gas Pressure Verification and Adjustment

Check Inlet Gas Pressure

Procedure to measure inlet gas pressure during maximum heat operation.

Adjust Manifold Pressure for Input Rate

Steps to adjust manifold pressure to achieve the correct gas input rate.

Temperature Rise Management

Furnace Damage Hazard from Incorrect Rise

Discusses risks of overheating heat exchangers and shortened furnace life from incorrect temperature rise.

Blower and Thermostat Control Adjustments

Check Safety Controls

Procedures for verifying the function of limit switches and pressure switches.

Service and Maintenance Procedures Overview

Diagnostic Code Retrieval and Component Testing

Retrieving Stored Fault Codes

Instructions on how to access and interpret stored fault codes from the control board.

Performing Component Self-Test

Guides through running a diagnostic test sequence for furnace components.

Routine Care and Maintenance

Air Filter Maintenance

Instructions for checking, cleaning, and replacing the furnace air filter.

Heat Exchanger Cleaning Procedures

Service Label and Control Diagnostics

Furnace Troubleshooting Guide

Diagnostic Flow Chart Navigation

Guide on how to use the flow chart to diagnose operational problems.

Sequence of Furnace Operation

Related product manuals