TABLE # 4.3
Technical specifications
TABLE # 5.3
Air delevery - CFM with air filter
Model : OLF / NOLF
RATING AND PERFORMANCE
Firing rate .50 .63 .75 .72
Pump pressure (PSIG) 100 156 156 145
Input (BTU/h) 70 000 88 200 105 000 100 800
Heating capacity, chimney installation (BTU/h) 59 200 73 000 87 800
Heating capacity, side-wall installation (BTU/h) 59 400 73 200 88 200 84 200
Minimum - maximum temperature rise
Stack draft, (Chimney), (Side-wall)
Overfire pressure (chimney), (Side-wall)
BECKETT BURNER, CHIMNEY INSTALLATION
Low firing rate baffle Yes Yes No
Static disc, model 2 3/4 #3383 2 3/4 #3383 2 3/4 #3383
Nozzle (Delavan) 0.50 - 70A 0.50 - 70A 0.60 - 70B
Combustion air adjustment (shutter / band) 4.5 / 0 8 / 0 7.5 / 0
RIELLO BURNER, CHIMNEY INSTALLATION
Nozzle (Delavan) 0.50 - 60A 0.60 - 60A
Combustion air adjustment (turbulator / damper) 0 / 3 0 / 4
BECKETT BURNER, SIDE-WALL INSTALLATION
Nozzle (Delavan) 0.50 - 60W 0.50 - 60W 0.60 - 60W
Combustion air adjustment (screw / dial) 3 / 1.5 3 / 3 3 / 4.5
RIELLO BURNER, SIDE-WALL INSTALLATION
Nozzle (Delavan) 0.50 - 60W 0.60 - 60W
Combustion air adjustment (turbulator / damper) 0 / 6 0 / 7.5
ELECTRICAL SYSTEM
Volts - Hertz - Phase
Operating voltage range
Rated voltage Amp
Minimum ampacity for wiring sizing
Max. fuse size (Amps)
Control transformer
Ext. control power available, cooling and accessories
BLOWER DATA
Blower speed at 0.5" W.C. static pressure LOW MED-HI HIGH HIGH
Blower speed at 0.25" W.C. static pressure LOW MED-HI HIGH HIGH
Maximum cooling, speed LOW MED-LO MED-HI HIGH
Maximum cooling, tons @ 5" W.C. 1.5 2 2.5 3
Motor (HP) / number of speeds
Blower wheel size (in.) 10 X 10
15
40 Va
30 Va
104 - 132
12,2
13.7
1/3 HP / 4 speeds
40-F3 (tube insersion 5 3/16")
AFII-85 (tube insersion 4 15/16")
40-BF3 (tube insersion 5 3/16")
115-60-1
OLF105A12B / NOLF105A12B
52 - 75 Degr. F
AFG-F0 (tube insersion 5 1/8")
(-0,035 to -0,06) (+0,04 to +0,16)
(0,00 to +0,035) (+0,10 to +0,25)
SPEED 0.25 0.5
LOW 840 770
MED-LO 960 800
MED-HI 1050 980
HIGH 1300 1200
OLF105A12B / NOLF105A12B
EXTERNAL STATIC PRESSURE WITH AIR FILTER