WATER CHILLERS
OPERATING AND MAINTENANCE MANUAL
iC 215 ÷ iC 780
38178800943
Original instructions in Italian language

Table of Contents

Questions and Answers

  • J
    Jeffrey HernandezAug 9, 2025
    Why is the ICS iC 520 tank water outlet temperature too high?
    • L
      Lindsey CampbellAug 9, 2025
      If the tank water outlet temperature (BTWOT) of your ICS Chiller is higher than the prescribed value, it could be due to several reasons. First, the thermal load might be too high; in this case, try to restore the thermal load to the prescribed limits. Secondly, the ambient temperature might be too high; if the unit is in an enclosed space, improve ventilation to reduce the ambient temperature to the recommended level. Also, check if the condenser fins are dirty and clean them if necessary. Ensure that the front surface of the condenser isn't blocked; if it is, remove the obstruction. Finally, it may be due to refrigerant fluid leak or compressor protection trips; in such cases, call a qualified refrigeration engineer to check for and fix any leaks and recharge the circuit.
  • K
    Karen MontgomeryAug 23, 2025
    What to do if there is insufficient pressure head at the ICS Chiller pump outlet?
    • E
      ehoganAug 25, 2025
      If you're experiencing insufficient water pressure at the pump outlet of your ICS Chiller, it could be due to an excessively high water flow rate. Try restoring the flow rate to the prescribed limits, perhaps by partially closing the pump outlet cock. Also, reset the pump thermal cutout and check the electrical power consumption. Alternatively, the evaporator might be clogged by impurities. Clean the evaporator by flushing it with a mild detergent suitable for steel, aluminum, and copper, and supply a high flow rate of water in countercurrent conditions. Consider installing a filter upstream from the unit.

Summary

USERS QUICK GUIDE

Unit Start;Stop Procedures

How to switch the unit on and off using the keypad or digital input.

SAFETY

General Safety Precautions

General safety rules and precautions for handling and maintaining the unit.

INSTALLATION

STARTING

Pre-Startup Checklist

Essential checks to perform before initiating unit startup procedures.

ELECTRONIC CONTROLLER

TROUBLESHOOTING

Troubleshooting Guide

A guide to identifying and resolving common problems with their causes and remedies.

RISK ANALYSIS: RESIDUAL RISK

ICS iC 520 Specifications

General IconGeneral
BrandICS
ModeliC 520
CategoryChiller
LanguageEnglish